DuPont™ Thermax™ XARMOR™ (ci) Exterior Insulation

Toughest, Most Durable Polyiso Insulation for the Thermax™ Wall System

thermax-xarmor-ci-exterior-product-logo-image1.jpg thermax-xarmor-ci-exterior-product-logo-image2.jpg thermax-xarmor-ci-exterior-product-logo-image3.jpg thermax-xarmor-ci-exterior-product-logo-image4.jpg thermax-xarmor-ci-exterior-product-logo-image5.jpg thermax-xarmor-ci-exterior-product-logo-image6.jpg thermax-xarmor-ci-exterior-product-logo-image7.jpg

DuPont™ Thermax™ XARMOR™ (ci) Exterior Insulation

Toughest, Most Durable Polyiso Insulation for the Thermax™ Wall System

<br><b>DuPont™ Thermax™ XARMOR™ (ci) Exterior Polyisocyanurate Insulation</b> is the toughest insulation for the patented Thermax™ Wall System. Designed for continuous insulation, <b>Thermax™ XARMOR™ (ci)’s</b> glass-fiber-reinforced polyisocyanurate foam core is homogenous – featuring finer cell size and better cell orientation, reducing voids and knit lines – resulting in one of the highest R-values available for immediate insulation and weather protection on the job site, as well as long-term thermal performance. <br><br> <b>Thermax™ XARMOR™ (ci) Insulation</b> is also the only Thermax™ Insulation with a dark exterior facer optimized to go behind rain screen exteriors. Its integral, durable thermoset-coated aluminum facer provides a drainage plane, water-resistive barrier and exterior sheathing; eliminating the need for a membrane, building wrap or exterior gypsum. Boasting a strong 4.0 mil embossed, acrylic-coated exterior foil facer, <b>Thermax™ XARMOR™ (ci) Insulation</b> provides builders with more durability for long-term performance. <br><br> With its low perm rating and high insulating value, <b>Thermax™ XARMOR™ (ci) Insulation</b> can help reduce the potential for condensation within the wall assembly. Thermax™ is also manufactured using a distinct free-rise technology using a unique fiberglass core for better product consistency, durability and fire performance than generic polyisocyanurate insulations.

Resources

Product Information Sheets Installation Guides Substitution Package Brochure Case Study Fire Performance Warranty

Features & Benefits

Ease of Installation
High Performance Durability
Moisture Resistant and UV Stability

Specifications

Standard Sizes

1.0 in.
4 ft.
8 ft.
7.0
Square Edge
1.55 in.
4 ft.
8 ft.
11.0
Square Edge, Shiplap
2.0 in.
4 ft.
8 ft.
13.0
Square Edge, Shiplap
2.5 in.
4 ft.
8 ft.
16.0
Shiplap
3.0 in.
4 ft.
8 ft.
19.0
Shiplap

Note: Please be advised that additional sizes may be available. Availability of all sizes varies by region and is subject to change. For further information, please contact your local DuPont Sales Representative or call us at 1-866-338-7668.

Testing

<b>Thermax™ XARMOR™ (ci) Insulation</b> exhibits the properties and characteristics indicated in the table below when tested as represented. Review all instructions and (Material) Safety Data Sheet ((M)SDS) before use. Please contact DuPont at 1-833-338-7668 when additional guidance is required for writing specifications that include this product.

FIRE
UL 723
Test Method for Surface Burning Characteristics of Building Materials
Surface Burning Characteristics1
Flame Spread ≤ 25
Smoke Developed ≤ 450
Core and Finished Product
NFPA 285
Standard Fire Test Method for Evaluation of Fire Propagation Characteristics of Exterior Wall Assemblies Containing Combustible Components
Fire Progagation - Exterior2
Pass
NFPA 286
Standard Methods of Fire Tests for Evaluating Contribution of Wall and Ceiling Interior Finish to Room Fire Growth
Fire Progagation - Interior
Pass
NFPA 268
Standard Test Method for Determining Ignitability of Exterior Wall Assemblies Using a Radiant Heat Energy Source
Ignitabiilty - Exterior
Pass
THERMAL
ASTM C518
Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus
Thermal Resistance 1 inch @ 75°F mean temp
7.0 F ft2h/Btu/in
ASTM D2126
Standard Test Method for Response of Rigid Cellular Plastics to Thermal and Humid Aging
Dimensional Stability
0.2% linear (length & width)
STRENGTH
ASTM D1621
Standard Test Method for Compressive Properties of Rigid Cellular Plastics
Compressive Strength
30 psi
ASTM C203
Standard Test Methods for Breaking Load and Flexural Properties of Block-Type Thermal Insulation
Flexural Strength
85 psi
ASTM D1623
Standard Test Method for Tensile and Tensile Adhesion Properties of Rigid Cellular Plastics
Tensile Strength
1000 psf
AIR
ASTM E2178
Standard Test Method for Determining Air Leakage Rate and Calculation of Air Permeance of Building Materials
Rate of Leakage
<0.02 L/s*m2
ASTM E2357
Standard Test Method for Determining Air Leakage Rate of Air Barrier Assemblies
Air Leakage
Pass
ASTM E283
Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Skylights, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen
Rate of Leakage
Pass
WATER
ASTM E96
Standard Test Methods for Gravimetric Determination of Water Vapor Transmission Rate of Materials
Water Vapor Permeance.
0.03 perm
ASTM C209
Standard Test Methods for Cellulosic Fiber Insulating Board
Water Absorption
0.1% volume
ASTM E331
Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference
Water Penetration
Pass

1Calculated flammability values for this or any other material are not intended to represent hazards that may be present under actual fire conditions.

2See Jensen Hughes engineering judgement

Code Compliance

<b>Thermax™ XARMOR™ (ci) Insulation</b> complies with the following codes:

US Product Listings & Verifications
ASTM C1289 - Type I, Class 2<br>2021, 2018, 2015, 2012, and 2009 International Residential Code (IRC)<br>2021, 2018, 2015, 2012, and 2009 International Building Code (IBC) <br>2021, 2018, 2015, 2012, 2009 International Energy Conservation Code (IECC)<br>2021, 2018, 2015, 2012 International Green Construction Code (IGCC<br>Thermax™ products are covered under Underwriters Laboratories Inc. (UL) File R5622 <br>UL 723 - Surface Burning Characteristics<br<br>UL 1256 - Fire Test of Roof Deck Constructions Nos. 99, 120 and, 123<br>UL 263 - The following designs are 1, 2, 3 or 4 hour wall rated assemblies as listed in the UL Fire<br>Resistance Directory: U026, U326, U330, U354, U355, U424, U425, U460, U902, U904, U905, U906, U907, V321, V322, V454, V482, V499, W404, W307, W413, W417, and W444<br>FM 4880 - Wall Construction Metal-Faced – Class 1 Fire Rated to Max. 30’ Exposure High, 3” Thick, 4’ Wide, When Installed as Described in the Current Edition of FMRC Approval Guide. Contact Dupont Technical Support for most current FM 4880 attachment requirements.
Regional Code Listings & Reports
2022 California Green Standards Code<br>California Bureau of Household Goods And Services Directory of Certified Insulation Materials - T 1534
US Code Reports
Intertek CCRR-0435<br>DrJ TER 1506-03

FAQ

What sets DuPont™ Thermax™ XARMOR™ (ci) Exterior Insulation apart from other Thermax products? Boasting a strong 4.0 mil embossed, acrylic-coated exterior foil facer, Thermax™ XARMOR™ (ci) provides builders with more durability for long-term performance. Thermax™ XARMOR™ (ci) is also the only Thermax™ insulation with a dark exterior facer optimized to go behind rain screen exteriors. In the USA, a 20-year limited thermal warranty is available. When used as a component in the Thermax™ Wall System, a 15-year limited water-resistance warranty is also available. Can DuPont™ Thermax™ Brand Insulation be left exposed to the building interior? Thermax™ Brand Insulation products can be left exposed to the building interior (i.e., without a thermal barrier such as 1/2 inch gypsum wallboard) in specific non-rated ceiling assemblies or non-rated construction in commercial, industrial and agricultural buildings. Thermax™ Brand Insulation products cannot be left exposed to exterior conditions.

The use of Thermax™ Brand Insulation exposed to the building interior is documented with a Code Compliance Research Report (CCRR-0440).

NOTE: Thermax™ cannot be used as a duct work or plenum insulation- it does not meet the IBC /IMC for flame spread of 25 or less and smoke developed of 50 or less

How much does DuPont™ Thermax™ XARMOR™ (ci) Exterior Insulation weigh? 0.216 lb/ft2
To get weight of 1 inch x 4 feet x 8 feet board multiple the value by 32
Example: Thermax™ XARMOR™ (ci) Insulation 1in x 4ft x 8ft weighs (0.216 x 32) = 6.9 lbs What are the ASTM C1289 classifications for DuPont polyisocyanurate products ? The ASTM C1289 classifications for DuPontpolyisocyanurate products are as shown below:

Type I, Class I
Tuff-R™ Insulation (< 1')
Type I, Class 2
Tuff-R™ Insulation (≥ 1')
Type I, Class 2
Thermax™ Basic NH Insulation
Type I, Class 2
Thermax™ Heavy Duty Insulation
Type I, Class 2
Thermax™ Light Duty NH Insulation
Type I, Class 2
Thermax™ XARMOR™ (ci) Exterior Insulation
Type I, Class 2
Thermax™ Metal Building Board NH Insulation
Type I, Class 2
Thermax™ White Finish NH Insulation

Type1 - Faced with aluminum foil on both major surfaces of the core foam. Class 1 - Non-reinforced core foam. Class 2 - Glass fiber reinforced core foam. Dimensional stability will be greater than Class 1 when fastened properly. ASTM C1289 Class 2 exceeds Class 1 requirements.