<br><b>DuPont™ Styrofoam™ Brand Cavitymate™ Plus Extruded Polystyrene (XPS) Insulation</b> is a moisture-resistant, durable and lightweight extruded polystyrene foam board specifically designed for use in wet cavity wall environments in commercial applications. Sized to fit snugly between wall ties, it is easy to handle, cut and install, saving time and money on the job site. <br><br>The closed-cell structure of <b>Styrofoam™ Brand Cavitymate™ Plus XPS Insulation</b> boards helps ensure exceptional long-term thermal performance and high moisture resistance.

Resources

Product Information Sheets Installation Guides Guide Specifications Technical Documents Brochure Codes & Certifications Fire Performance Warranty

Features & Benefits

Convenient Size
Lightweight and Durable

Specifications

Standard Sizes

2 in.
16 in.
8 ft.
10
Butt Edge
3 in.
16 in.
8 ft.
15
Butt Edge

Note: Please be advised that additional sizes may be available. Availability of all sizes varies by region and is subject to change. For further information, please contact your local DuPont Sales Representative or call us at 1-866-338-7668.

Testing

<b>Styrofoam™ Brand Cavitymate™ Plus XPS Insulation</b> exhibits the properties and characteristics indicated in the table below when tested as represented. Review all instructions and (Material) Safety Data Sheet ((M)SDS) before use. Please contact DuPont at 1-833-338-7668 when additional guidance is required for writing specifications that include this product.

FIRE
UL 723
Test Method for Surface Burning Characteristics of Building Materials
Surface Burning Characteristics
Flame Spread ≤ 25
Smoke Developed ≤ 450
THERMAL
ASTM C518
Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus
Thermal Resistance per inch @ 75°F mean temp1
5.0 ft2
•h•°F/Btu, R-value, min.
ASTM D696
Standard Test Method for Coefficient of Linear Thermal Expansion of Plastics Between −30°C and + 30°C with a Vitreous Silica Dilatometer
Coefficient of Linear Thermal Expansion
3.5 x 10-5
in/in•°F
ASTM D2126
Standard Test Method for Response of Rigid Cellular Plastics to Thermal and Humid Aging
Change in Dimensions
2.0% change, max.
STRENGTH
ASTM D1621
Standard Test Method for Compressive Properties of Rigid Cellular Plastics
Compressive Strength2
25 psi, min.
ASTM C203
Standard Test Methods for Breaking Load and Flexural Properties of Block-Type Thermal Insulation
Flexural Strength
50 psi, min.
WATER
ASTM C272
Standard Test Method for Water Absorption of Core Materials for Sandwich Construction
Water Absorption
0.3% by volume, max.
ASTM E96
Standard Test Methods for Gravimetric Determination of Water Vapor Transmission Rate of Materials
Water Vapor Permeance3
1.5 perm, max.

1Values are consistent with the criteria of ASTM C578 and the requirements of the FTC R-value rule (16 CFR Part 460). R means resistance to heat flow. The higher the R-value, the greater the insulating power.

2Vertical compressive strength is measured at 10 percent deformation or at yield, whichever occurs first. Since Styrofoam™ Brand Extruded Polystyrene Foam Insulations are visco-elastic materials, adequate design safety factors should be used to prevent long-term creep and fatigue deformation.

3Based on 1” thickness.

Code Compliance

<b>Styrofoam™ Brand Cavitymate™ Plus XPS Insulation</b> complies with the following codes:

US Product Listings & Verifications
International Residential Code (IRC) and International Building Code (IBC); see ICC-ES ESR-4755<br>Underwriters Laboratories, Inc. (UL) Classified, see Classification Certificate D-369<br>DrJ TER 1303-01
Regional Code Listings & Reports
California Std. Reg. #CA T1535