Tyvek / DuPont™ Tychem® 6000 SFR
FS275T LT
DuPont™ Tychem® 6000 SFR
DuPont™ Tychem® 6000 SFR Sleeved Apron. Offers broad chemical protection and secondary flame resistance in a lightweight garment. Must be worn over appropriate primary FR clothing. Light tan, knee-length (44" long) apron with attached sleeves features a hook and loop closure, waist ties, and taped seams. Suitable for refineries, petrochemical plants, laboratories, and hazardous maintenance operations.
-
With Permeation Data
Without Permeation Data
-
DOUBLE CHECK Use Double Check to determine if this product is suitable for your hazard scenario.
-
Buy Now
Distributors in the United States
Authorized Wholesalers in the United States (Distributors Only)
Frequently Asked Questions
FS275T LT
DuPont™ Tychem® 6000 SFR
In what ways can I manage or prevent heat stress? Chemical protective clothing can interfere with the natural regulation of body temperature. This can lead to a rise in core body temperature and heat stress. Implementing a conservative work/rest schedule or using a cooling system may be effective in reducing heat stress. (Note: Do not wear cooling vests in potentially flammable or explosive environments.) .)
Be aware of the symptoms and treatment of heat stress. If you or your co-workers have symptoms of heat stress such as nausea, dizziness, high heart rates, or excessive heat build-up, leave the work area immediately and remove the ensemble as quickly as possible after decontamination and seek professional care.
The maximum length of time the chemical protective clothing can be worn depends on variables such as the air supply, ambient conditions, climate inside the ensemble, physical and psychological conditions of the wearer, work rate and work load. The TLV® pocket guide from the American Conference of Governmental Industrial Hygienists (ACGIH, Cincinnati) provides corrected heat stress limits for some garments. Similar information is available on the federal OSHA web site (www.OSHA.gov). The WBGT correction factor for chemical protective garments is at least 10°C or higher for chemical garments made of impervious films (such as Tychem® garments) and covering the entire body (hooded coverall or encapsulating designs). For Tyvek® coveralls, the WBGT correction factor is 2°C with a hood and 1°C without a hood. What are the donning and doffing instructions for Tychem® 6000 SFR coveralls? Please refer to the Section on Donning and Doffing Non-Encapsulating Garments in the Tychem® User Manual - Non-Encapsulated. What determines if the garment is contaminated? The decision on whether or not a garment has been contaminated is made by local managers responsible for PPE based on an analysis of the incident in which the garment was used. This analysis may include exposure time, chemicals involved, level of exposure, proximity to the actual release, tasks performed, and environmental monitoring in the area in which the garment was worn.
Garments that are damaged, altered, or show signs of contamination, such as discoloration, odor, stiffening or cracks, should not be used. Are Tychem® 6000 SFR garments latex free?
After January 2023, all DuPont Personal Protection product styles are manufactured under specifications that exclude components containing natural rubber latex.
Tyvek® 500, Tyvek® 600, Tyvek® 800 products manufactured before January 2023 did contain natural rubber latex which may cause allergic reactions in some sensitized individuals. Anyone who begins to exhibit an allergic response during the use of DuPont products should immediately cease using these products. The incident should also be reported to DuPont at +1 (888) 439-2988 so that an investigation can be initiated.
How are Tychem® 6000 SFR garments different from Tychem® 6000 FR garments? Tychem® 6000 SFR garments are secondary flame-resistant garments, while Tychem® 6000 FR garments (discontinued effective 1H 2024) were primary flame-resistant garments.
Tychem® 6000 SFR garments provide only secondary flame resistance and must always be worn over appropriate primary flame-resistant protective clothing in an environment that requires flame protection, along with other personal protective equipment that protects your head, face, hands and feet. In addition, for Tychem® 6000 SFR hooded garments, a primary flame-resistant hood/balaclava should be worn.
Tychem® 6000 FR garments (discontinued effective 1H 2024) were primary FR garments, designed to provide stand-alone protection from flame and arc exposures.
Tychem® 6000 SFR fabric offers a similar level of chemical protection to Tychem® 6000 FR fabric, providing at least 30 minutes of protection for more than 180 chemical challenges including chemical warfare agents, toxic industrial chemicals, and flammable organic solvents. Can Tychem® 6000 SFR garments be used as primary flame-resistant (FR) garments? No. Primary flame-resistant (FR) garments, such as those made with DuPont™ Nomex® Essential (Nomex® IIIA) fabric, can be worn alone to provide the necessary level of protection from a flame/thermal threat. Garments made of Tychem® 6000 SFR fabric are not substitutes for primary flame-resistant protective garments. DuPont™ Tychem® 6000 SFR garments provide only secondary flame-resistant protection and are engineered to be worn over primary flame resistant / thermal protective garments to provide barrier protection from a broad range of chemicals including chemical warfare agents, toxic industrial chemicals, and flammable organic solvents while not contributing to burn injury in the event of a flash fire. They must always be worn over an appropriate primary flame-resistant garment in an environment that needs flame protection, along with other personal protective equipment that protects your face, hands, and feet. In addition, for Tychem® 6000 SFR hooded garments, a primary flame-resistant hood/balaclava should be worn. Do Tyvek® 6000 SFR garments meet ANSI/ISEA 101 sizing standards? How should Tychem® 6000 SFR garments be stored? Store Tychem® 6000 SFR garments in a cool, dark, dry location free of dirt and insects. Sunlight, ozone, high temperatures (>120° F ; 49° C), vehicle exhaust fumes, compression under heavy weights and sharp edges or projections are some conditions known to degrade the materials in these garments.
Store Tychem® 6000 SFR garments in boxes, in bags or on hangers. Never step on protective garments. Never place or store heavy objects on top of protective garments. Is it possible to wash and re-use Tychem® 6000 SFR garments? DuPont does not recommend washing Tychem® 6000 SFR garments for re-use. These garments are designed for limited-use. They can be worn until damaged, altered or contaminated. How are Tychem® 6000 SFR garments different from Tychem® 6000 garments? Tychem® 6000 SFR garments provide broad chemical protection and secondary flame-resistance for use in environments where chemical splash and flash fire dual hazards exist. They must always be worn over appropriate primary flame-resistant protective clothing in an environment that requires flame protection, along with other personal protective equipment that protects your head, face, hands and feet. In addition, for Tychem® 6000 SFR hooded garments, a primary flame-resistant hood/balaclava should be worn.
Tychem® 6000 SFR fabric offers a similar level of chemical barrier protection to Tychem® 6000 fabric, providing at least 30 minutes of protection for more than 180 chemical challenges including chemical warfare agents and toxic industrial chemicals.
On the contrary, Tychem® 6000 garments provide broad chemical protection however they are NOT flame-resistant and should not be used around heat, flames, sparks or in potentially flammable or explosive environments. Tychem® 6000 garments will burn and possibly melt if exposed to a fire or electric arc flash; this may increase burn injuries even when worn over garments made of Nomex® or any other flame-resistant fabric. What is the shelf life of Tychem® 6000 SFR garments? Tychem® garments may be used for 5 years from the date of manufacture as long as all of the following conditions are met:
- The garment has been stored properly (view storage conditions)
- The garment has not been damaged, altered or contaminated
- The garment passes a full visual inspection (view garment inspection instructions)
What is the difference between primary and secondary flame resistant (FR) garments? Primary flame-resistant garments are designed to provide stand-alone protection from flame and arc exposures. Common examples are garments made with DuPont™ Nomex® Essential (Nomex® IIIA). Primary flame-resistant garments selected based on the hazard analysis can provide protection from burn injury in the event of an industrial fire or electric arc exposure even when worn alone.
Secondary flame-resistant garments are made with fabrics that are designed to self-extinguish with no or short after-flame once the flame/heat source is removed. Secondary flame-resistant garments are not expected to contribute to additional burn injury if exposure to heat and flame occurs when worn over an appropriate primary flame-resistant garment. Secondary flame-resistant garments like ProShield® 6 SFR, Tyvek® 400 SFR, Tychem® 2000 SFR, and Tychem® 6000 SFR are not expected to provide the wearer any protection from burn injury in the event of a flash fire when worn stand-alone without primary flame-resistant garments underneath. What is the ambient working temperature range for Tychem® 6000 SFR garments? Tychem® garments can be worn in ambient temperatures of -13°F (-25°C) to 165°F (74°C).
In colder environments, Tychem® garments can become stiff. If cold enough, the fabric may even become brittle. Please be aware that the heat stress of the wearer becomes a greater concern in higher ambient temperatures. At higher temperatures, chemical hazards can become more aggressive. Breakthrough times and permeation rates may change at higher temperatures. The published permeation data per ASTM F739 is performed at ambient temperatures (approximately 72-81° F ; 22-27° C).
Caution: Tychem® fabrics offer little or no thermal insulation to protect the wearer's skin from prolonged exposure to hot or cold. What is secondary flame-resistant (SFR) protective clothing? Secondary flame-resistant (SFR) protective clothing is made with fabrics that are designed to self-extinguish with no or short after-flame once the flame/heat source is removed. Secondary flame-resistant protective clothing must always be worn over appropriate primary flame-resistant protective clothing in an environment that requires flame protection, such as garments made with DuPont™ Nomex® Essential (Nomex® IIIA) or Nomex® Comfort fabric, along with other personal protective equipment that protects your head, face, hands and feet. Secondary flame-resistant garments are not expected to contribute to additional burn injury if exposure to heat and flame occurs when worn over an appropriate primary flame-resistant (FR) garment. Secondary flame-resistant garments are not expected to provide the wearer any protection from burn injury in the event of a flash fire when worn stand-alone without primary flame-resistant garments underneath.
Secondary flame-resistant protective garments like ProShield® 6 SFR, Tyvek® 400 SFR, Tychem® 2000 SFR, and Tychem® 6000 SFR are designed to provide protection against particulate and/or liquid chemical hazards, while not negatively impacting the burn performance of the primary FR garments worn underneath. When selecting a secondary flame-resistant (SFR) protective garment, it is important to examine both the flame-resistant (FR) requirements and perform a hazard assessment for hazardous and nonhazardous particles, liquids, or chemicals. Visit DuPont™ SafeSPEC™ to learn more about the DuPont SFR garment portfolio and the specified hazards they help protect against. Are Tychem® 6000 SFR garments anti-static or static dissipative? The substrate used to make Tychem® 6000 SFR garments is treated with a topical antistatic agent to help minimize static build up and reduce nuisance garment cling.
In situations where static dissipation level is a critical performance property, end-users should evaluate the performance of their entire ensemble as worn including outer garments, inner garments, footwear and other PPE. In order for any garment system to be static dissipative, it must be able to drain a charge buildup through proper grounding devices, such as, but not limited to, workstation grounding clips or static-dissipative floors.
Under certain conditions, such as cold and dry weather, it is possible that garments might build and discharge static electricity. Discharges are not normally dangerous except in situations where the generation of an electrical spark could ignite a flammable atmosphere or startle the wearer. When operating around flammable chemicals, take steps to eliminate potential static discharges. In these situations, suggested steps include, but not limited to, water spray, the use of an overcover, raising humidity level of the work area, use of a commercial, anti-static application coating, grounding straps on equipment and personnel, inherently static-dissipating under- and over-garments, and testing of the worker's static dissipation before entry into the classified area.
However, in the case of explosive or flammable atmospheres, even if steps are taken to manage static formation and dissipate static charge, the risk of severe injury remains if an uncontrolled or accidental ignition occurs. Do not wearTychem® 6000 SFR chemical protective garments in potentially flammable or explosive atmospheres. Do not knowingly enter an environment in which the concentration of flammable gas is within flammable or explosive limits while wearing a Tychem® 6000 SFR garment. If you determine that you are in a potentially flammable or explosive environment, retreat immediately. In what ways can I dispose of Tychem® 6000 SFR garments? In the United States, if not contaminated with chemical or biological hazards, Tyvek® 400 SFR garments can be recycled for non-hazardous applications through the Tyvek® Protective Apparel Recycling Program.Contact DuPont Personal Protection Customer Service at 1-800-931-3456 for information.
Tyvek® 400 SFR garments may be landfilled or incinerated in accordance with local regulations. Uncontaminated chemical protective garments may be incinerated in a facility that is capable of handling mixtures containing plastics. Likewise, an uncontaminated chemical protective garment may be buried in a facility that accepts plastic materials.
Contaminated garments that cannot be handled safely without protective equipment must be disposed of with other hazardous wastes, either through incineration or landfill per local regulations. Before discarding, cut off a sleeve or a leg so the garments cannot be worn again as protective clothing. Where can I find a SDS (Safety Data Sheet) for Tychem® 6000 SFR garments? Safety Data Sheets (SDS) are written in accordance with applicable federal regulations, 29 CFR 1910.1200, to communicate health and safety data on usage and handling of hazardous chemicals. Under this regulation, DuPont™ Tyvek®, ProShield®, and Tychem® materials and garments are defined as articles, not chemicals, and the SDS and labeling requirements in that standard do not apply. Why isn’t there a claim made re: NFPA 701: Standard Methods of Fire Tests for Flame Propagation of Textiles and Films for this garment? NFPA 701 is only appropriate for textile materials used in furnishings such as curtains, draperies or window treatments; or for decorative purposes, awnings, tents, tarps and banners, this standard is not appropriate to asses “FR” performance of clothing. Will Tychem® 6000 SFR fabric burn? When exposed to a flame, the Tychem® 6000 SFR fabric will shrink away. In the event that a flash fire occurs, Tychem® 6000 SFR garments will not contribute to additional burn injury if appropriate primary flame-resistant personal protective equipment is worn beneath. When the flame source is removed, the Tychem® 6000 SFR fabric will self-extinguish with no or short after-flame. However, garments made of Tychem® 6000 SFR must not be used alone in areas where protection from fire or electric arc is required. They are designed to be worn over primary FR garments and ensembles. I’m not in an environment that needs FR clothing. Can I still wear Tychem® 6000 SFR garments? Yes, if Tychem® 6000 SFR is suitable for use for the specified chemical hazard, it can be worn. Tychem® 6000 SFR garments provide at least 30 minutes of protection for more than 180 chemical challenges including chemical warfare agents, toxic industrial chemicals, and flammable organic solvents. However, if flame hazard is not present, Tychem® 6000 garments can be used instead. Tychem® 6000 fabric offers a similar level of chemical barrier protection to Tychem® 6000 SFR fabric.
DUPONT™ SAFESPEC™ Terms of Use
Product Selector Agreement
The following information must be read and accepted by the user before proceeding.
The DuPont™ SafeSPEC™ Product Selector Tool (“Tool”) is intended to assist in choosing protective clothing styles for particular applications and does not replace the judgment of a qualified safety professional or industrial hygienist. Additional personal protective equipment (“PPE”), such as but not limited to: respiratory, eye, head, foot, and hand protection, may be required. Supplying the proper hazard/chemical and exposure information for your hazard scenario is critical in order to obtain suggestions of possible garment options for your consideration. Inaccurate information could result in improper suggestions. Since there are other factors involved which could affect the final PPE decision and may not be considered in this Tool, the final decision on protective clothing selection is the responsibility of the buyer, safety professional, industrial hygienist and end-user. DuPont de Nemours, Inc. or its affiliates DISCLAIM ANY RESPONSIBILITY OR LIABILITY FOR ANY INFORMATION OR SUGGESTIONS PROVIDED BY THE TOOL OR THE USE THEREOF.
WARNING / CAUTION
There are uses, environments and chemicals for which any garment will be unsuitable. It is the responsibility of the user to review available data and verify that the garment selected is appropriate for the intended use and meets all specified government and industry standards.
Search by :
1 Choose Hazards
1 Enter
Chemicals
2 View Permeation Data
2 View
Data
3 View Matching Products
3 View
Products
Step 1 of 3
You may enter from one to five chemicals or other hazards that may be present in your working environment. Our tool will find the best product match for the combined hazards. Enter a single chemical or hazard if you wish to find the best possible product match for that one hazard.
Chemical or Other Hazard Name
Enter at least 3 characters and select hazard from list.
or
CAS Number
Synonyms, Class and Sub-Class information
Hazard Concentration information
Please read following
- You have selected a chemical that has been tested at multiple concentrations. All concentrations will be displayed on the next page so that you can review breakthrough times for each concentration.
- Please review FAQs if your hazard concentration is lower or higher than the tested concentrations
Read FAQ if your Hazard concentration is lower than the tested concentration Read FAQ if your Hazard concentration is higher than the tested concentration
Need Help?
- If you see your CAS number in the drop down list, make sure you are selecting the hazard from the drop down list before clicking "Add to List".
- If you do not see your CAS number listed, check the number and try again or you may want to try Guide.
1 Choose Hazards
1 Enter
Chemicals
2 View Permeation Data
2 View
Data
3 View Matching Products
3 View
Products
Step 2 of 3
CHEMICAL COMPARISON
The table below shows the Normalized Breakthrough times of fabrics for the hazards selected. (Testing Details) You can find specific garments that protect against these hazards by clicking the 'Next' button below.
Done
btAct
Done
btAct
Done
<< BACK TO CHEMICAL LIST
1 Choose Hazards
1 Enter
Chemicals
2 View Permeation Data
2 View
Data
3 View Matching Products
3 View
Products
Step 3 of 3
Exposure
Please provide a response to all exposure questions before proceeding.
Flammable Environments
WARNING
If any of the following apply:
- A fire or electric arc is actively present in the work environment
- The work environment contains an uncontrollable flammable material between the Lower Explosive Limit (LEL) or Lower Flammable Limit (LFL) and the Upper Explosive Limit (UEL) or Upper Flammable Limit (UFL)
- The work environment has been subject to a breach or loss in containment of flammable material (flammable liquids, flammable vapors or combustible dusts)
- There is an uncontrolled fuel source available in the work environment (that may or may not have encountered an ignition source yet)
STOP USING THIS TOOL. Please consider fire fighter PPE (personal protective equipment). Read more.
If none of these conditions apply but FR clothing is required in your working environment, close this box and proceed to the next question. Only fabrics that provide both chemical resistance to the hazards you have listed and protection during escape from a flash fire will be considered for your hazard scenario.
1 Choose Hazards
1 Enter
Chemicals
2 View Permeation Data
2 View
Data
3 View Matching Products
3 View
Products
step3of3
Is Suitable For Hazard Scenario
Is Not Suitable For Hazard Scenario
Compare All
YOU MAY WANT TO CONSIDER SIMILAR PRODUCTS RELATED TO FS275T LT
Matching Products (0)
Your hazard scenario did not produce any results. May we suggest:
- If you are searching multiple hazards at one time, try breaking your search into separate hazards by either creating a new scenario or unchecking Hazards in the pane to the left. SafeSPEC™ is trying to find one garment that can be used for all of your hazards. You may need to consider more than one garment.
- If you have a liquid or vapor chemical hazard, try searching the Chemical Resistance Database. This database will show you permeation data for all of the fabrics tested against a given hazard. Once you are able to determine a suitable fabric, you will have the flexibility of selecting a suitable garment design and seam construction yourself.
- If you answered "yes" to the question that you are working in an environment that requires flame resistant clothing, please note that although DuPont has several garment options for scenarios involving possible industrial fire or electric arc exposures as well as chemical exposure hazards, these garments may not have been tested against the specific chemical hazard(s) that you have selected or may have breakthrough times lower than your intended work duration. If possible, try to mitigate the need for flame resistant clothing by implementing engineering controls, work practices and administrative controls before resorting to protective clothing. Additionally, try breaking your search into separate hazards as suggested above in order to find garment options to meet your needs.
- If you selected "localized to the feet" for the direction of exposure question, you may want to consider chemical resistant boots instead of purchasing a full garment. DuPont does not manufacture or sell chemical resistant boots. However, we do offer some coveralls and encapsulated suits with attached socks. These socks can be worn as an extra layer of protection inside of chemical resistant boots.
If you still need help, please Contact Us.
For a general fabric overview, please view our
SELECT FROM SAVED SCENARIO
Please select the Scenario you have saved for the
Saved Scenario for
Is Suitable For Hazard Scenario
Is Not Suitable For Hazard Scenario
Compare All
YOU MAY WANT TO CONSIDER SIMILAR PRODUCTS RELATED TO FS275T LT
For a general fabric overview, please view our
Hazards Matrix
Hover over image to zoom
Technical Data Sheet
FEATURES & PRODUCT DETAILS
DuPont™ Tychem® 6000 SFR garments provide broad chemical protection and secondary flame resistance in a durable, lightweight garment for use in environments where chemical splash and flash fire hazards exist. Designed to be worn over primary flame-resistant protective clothing, Tychem® 6000 SFR garments help provide industrial workers and hazmat responders with permeation protection against a range of chemicals while providing escape time from flash fires. Tychem® 6000 SFR fabric provides at least 30 minutes of protection for more than 250 chemical challenges including chemical warfare agents, toxic industrial chemicals, and flammable organic solvents.
In the event that a flash fire occurs, Tychem® 6000 SFR garments won't contribute to additional burn injury if appropriate primary flame-resistant personal protective equipment is worn beneath.
Applications include: oil & gas, industrial chemical processing plants, laboratories, hazmat teams in fire departments, industrial fire brigades, and clandestine lab investigation.
- Knee-length apron/gown design with attached sleeves.
- Provides enhanced frontal protection.
- 44" long for neck-to-knee coverage.
- Open back for wearer comfort
- Hook & loop closure.
- Ties at waist.
- Elastic opening for tighter fit at wrist.
- Available in multiple sizes.
- Taped seams provide strong chemical resistance against heavy liquid splashes. A sewn seam is covered with a strip of compatible chemical-resistant material through heat sealing.
- Products made after January, 2023 are manufactured under specifications that do not contain natural rubber latex.
- Meets the U.S. industry requirements for blood (ASTM F1670) and viral penetration (ASTM F1671) protecting against several bloodborne pathogen exposure risks.
AVAILABLE OPTIONS
SPECIFICATIONS
- The garment shall be constructed of DuPont™ Tychem® 6000 SFR-- a proprietary secondary flame-resistant (FR) chemical fabric.
- The garment shall be light tan in color.
- The garment shall be a sleeved apron design.
- The garment shall have taped seams.
- The tape used to cover the seams shall be a film composite with equal to or greater chemical resistance than the base fabric.
- The garment shall have waist ties.
- The garment shall be 44 inches in length.
- The garment shall have elastic wrists.
- The garment shall have a hook and loop neck closure.
FINISHED DIMENSIONS
ADDITIONAL EQUIPMENT NEEDED
- Please read, understand and follow the Tychem® User Manual.
- Tychem® 6000 SFR garments provide only secondary flame-resistant protection. They must always be worn over appropriate primary flame-resistant protective clothing in an environment that needs flame protection, along with other personal protective equipment that protects your face, hands, and feet. For Tychem® 6000 SFR hooded garments, a primary flame-resistant hood/balaclava should be worn.
- Wear other appropriate PPE such as, but not limited to, respiratory, eye, head, hand, and foot protection based on the hazard assessment.
FABRIC & CHEMICAL RESISTANCE DATA
Physical Properties
Data relating to mechanical performance of the fabrics used in DuPont chemical protective clothing, listed for the selected garment according to the test methods and relevant European standard, if applicable. Such properties, including abrasion and flex-cracking resistance, tensile strength and puncture resistance can help in the assessment of protective performance.
Featured resources Download Permeation Guide
CHEMICAL RESISTANCE
- BT0.1 Normalized breakthrough time at 0.1 µg/cm²/min [mins]
- CAS Chemical abstracts service registry number
- min Minute
- > Larger than
- < Smaller than
- imm Immediate (< 10 min)
- nm Not tested
- sat Saturated solution
- N/A Not Applicable
- na Not attained
- GPR grade General purpose reagent grade
- * Based on lowest single value
- 8 Actual breakthrough time; normalized breakthrough time is not available
- DOT5 Degradation after 5 min
- DOT30 Degradation after 30 min
- DOT60 Degradation after 60 min
- DOT240 Degradation after 240 min
- BT1383 Normalized breakthrough time at 0.1 µg/cm²/min [mins] acc. ASTM F1383
SPECIAL WARNINGS
- Tychem® 6000 SFR garments provide only secondary flame-resistant protection. They must always be worn over appropriate primary flame-resistant protective clothing in an environment that needs flame protection, along with other personal protective equipment that protects your face, hands, and feet. For Tychem® 6000 SFR hooded garments, a primary flame-resistant hood/balaclava should be worn.
- Do not knowingly enter an environment in which the concentration of flammable gas is within flammable or explosive limits when wearing a Tychem® 6000 SFR garment. Retreat immediately if you encounter such an environment.
- Tychem® 6000 SFR garments are not intended for firefighting activities, nor for protection from hot liquids, steam, molten metals, welding, or thermal radiation.
- *CAUTION: This information is based upon technical data that DuPont believes to be reliable. It is subject to revision as additional knowledge and experience are gained. DuPont makes no guarantee of results and assumes no obligation or liability in connection with this information. It is the user's responsibility to determine the level of toxicity and the proper personal protective equipment needed. The information set forth herein reflects laboratory performance of fabrics, not complete garments, under controlled conditions. It is intended for informational use by persons having technical skill for evaluation under their specific end-use conditions, at their own discretion and risk. Anyone intending to use this information should first verify that the garment selected is suitable for the intended use. In many cases, seams and closures have shorter breakthrough times and higher permeation rates than the fabric. Please contact DuPont for specific data. If fabric becomes torn, abraded or punctured, or if seams or closures fail, or if attached gloves, visors, etc. are damaged, end user should discontinue use of garment to avoid potential exposure to chemical. Since conditions of use are outside our control, DUPONT DE NEMOURS, INC. AND ITS AFFILIATES MAKE NO WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE AND ASSUMES NO LIABILITY IN CONNECTION WITH ANY USE OF THIS INFORMATION. This information is not intended as a license to operate under or a recommendation to infringe any patent or technical information of DuPont or others covering any material or its use
View by: View all resources ✕ ✕ To access secured content from DuPont Please Sign In or Sign Up below Sign In New User ? Sign Up