Tyvek / DuPont™ Tychem® 4000

SL127B WH

DuPont™ Tychem® 4000

DuPont™ Tychem® 4000 Hooded Coverall. Offers rugged, durable protection against a wide range of chemicals. White coverall features a standard fit hood, elastic wrists and ankles, a storm flap with adhesive closure, bound seams, and a pin lock slider zipper pull. Suitable for a variety of applications, including hazardous remediation, nuclear environments, waste management, and chemical handling.

Share

Frequently Asked Questions

SL127B WH

DuPont™ Tychem® 4000

Do TYCHEM® 4000 garments meet ANSI/ISEA 101 sizing standards? Yes. DuPont™ TYCHEM® 4000 coveralls either meet or exceed ANSI/ISEA 101 sizing standards. For specific sizing dimensions on a particular DuPont garment, please view the Product Details tab for that garment. What is the ambient working temperature range for TYCHEM® 4000 garments? Tychem® garments can be worn in ambient temperatures of -13°F (-25°C) to 165°F (74°C).
In colder environments, Tychem® garments can become stiff. If cold enough, the fabric may even become brittle. Please be aware that the heat stress of the wearer becomes a greater concern in higher ambient temperatures. At higher temperatures, chemical hazards can become more aggressive. Breakthrough times and permeation rates may change at higher temperatures. The published permeation data per ASTM F739 is performed at ambient temperatures (approximately 72-81° F ; 22-27° C).

Caution: Tychem® fabrics offer little or no thermal insulation to protect the wearer's skin from prolonged exposure to hot or cold. In what ways can I manage or prevent heat stress? Chemical protective clothing can interfere with the natural regulation of body temperature. This can lead to a rise in core body temperature and heat stress. Implementing a conservative work/rest schedule or using a cooling system may be effective in reducing heat stress. (Note: Do not wear cooling vests in potentially flammable or explosive environments.) .)

Be aware of the symptoms and treatment of heat stress. If you or your co-workers have symptoms of heat stress such as nausea, dizziness, high heart rates, or excessive heat build-up, leave the work area immediately and remove the ensemble as quickly as possible after decontamination and seek professional care.

The maximum length of time the chemical protective clothing can be worn depends on variables such as the air supply, ambient conditions, climate inside the ensemble, physical and psychological conditions of the wearer, work rate and work load. The TLV® pocket guide from the American Conference of Governmental Industrial Hygienists (ACGIH, Cincinnati) provides corrected heat stress limits for some garments. Similar information is available on the federal OSHA web site (www.OSHA.gov). The WBGT correction factor for chemical protective garments is at least 10°C or higher for chemical garments made of impervious films (such as Tychem® garments) and covering the entire body (hooded coverall or encapsulating designs). For Tyvek® coveralls, the WBGT correction factor is 2°C with a hood and 1°C without a hood. How should TYCHEM® 4000 garments be stored? Store TYCHEM® 4000 garments in a cool, dark, dry location free of dirt and insects. Sunlight, ozone, high temperatures (>120° F ; 49° C), vehicle exhaust fumes, compression under heavy weights and sharp edges or projections are some conditions known to degrade the materials in these garments.

Store TYCHEM® 4000 garments in boxes, in bags or on hangers. Never step on protective garments. Never place or store heavy objects on top of protective garments. Are TYCHEM® 4000 garments anti-static or static dissipative? The substrate used to make TYCHEM® 4000 garments is treated with a topical antistatic agent to help minimize static build up and reduce nuisance garment cling.

In situations where static dissipation level is a critical performance property, end-users should evaluate the performance of their entire ensemble as worn including outer garments, inner garments, footwear and other PPE. In order for any garment system to be static dissipative, it must be able to drain a charge buildup through proper grounding devices, such as, but not limited to, workstation grounding clips or static-dissipative floors.

Under certain conditions, such as cold and dry weather, it is possible that garments might build and discharge static electricity. Discharges are not normally dangerous except in situations where the generation of an electrical spark could ignite a flammable atmosphere or startle the wearer. When operating around flammable chemicals, take steps to eliminate potential static discharges. In these situations, suggested steps include, but not limited to, water spray, the use of an overcover, raising humidity level of the work area, use of a commercial, anti-static application coating, grounding straps on equipment and personnel, inherently static-dissipating under- and over-garments, and testing of the worker's static dissipation before entry into the classified area.

However, in the case of explosive or flammable atmospheres, even if steps are taken to manage static formation and dissipate static charge, the risk of severe injury remains if an uncontrolled or accidental ignition occurs. Do not wearTYCHEM® 4000 chemical protective garments in potentially flammable or explosive atmospheres. Do not knowingly enter an environment in which the concentration of flammable gas is within flammable or explosive limits while wearing a TYCHEM® 4000 garment. If you determine that you are in a potentially flammable or explosive environment, retreat immediately. Can TYCHEM® 4000 garments be worn in cleanroom applications? TYCHEM® 4000 garments have not been designed for controlled environment applications. DuPont offers a full line of garments that have been specially manufactured, processed and packaged for use in controlled environment applications. Please see our complete line of controlled environment products at www.safespeccleanroom.dupont.com. Are TYCHEM® 4000 garments flame resistant or flame retardant (FR)? Other than Tychem® 6000 FR, Tychem® chemical protective garments will ignite and continue to burn.

Wearing garments made of Nomex® or any other flame-resistant fabric under Tychem® garments, other than Tychem® 6000 FR, will not reduce burn injury during a fire or electric arc exposure. Other than Tychem® 6000 FR, Tychem® garments will burn and possibly melt when exposed to a fire or electric arc flash; this may increase burn injuries even when worn over garments made of Nomex® or any other flame-resistant fabric.

And because Tychem® garments melt, except for Tychem® 6000 FR do not wear Tychem® garments under a garment made of Nomex® or any other flame resistant fabric if the potential for fire or electric arc flash exists.

Do not knowingly enter an environment in which the concentration of flammable gas is within flammable or explosive limits when wearing a Tychem® garment, including when wearing a Tychem® 6000 FR garment. Retreat immediately if you encounter such an environment while wearing any Tychem® garment, including Tychem® 6000 FR.

No Tychem® garment, including Tychem® 6000 FR,is intended for fire fighting activities, nor for protection from hot liquids, steam, molten metals, welding, or thermal radiation. Tychem® 6000 FR garments are designed and tested to help reduce injury during escape from a fire and to provide some protection from electric arcs. Do TYCHEM® 4000 products contain silicone? All DuPont Personal Protection products are manufactured under specifications that do not contain silicone, with some exceptions. Tyvek® friction-coated shoe covers or Tyvek® garments with friction-coated shoe covers might contain silicone. This includes Tyvek® styles TY122, TY121, FC450 and FC454. Additionally, Tychem® 6000 AL styles TF630 and TF640T contain a silicone valve diaphragm. End users who are consuming these styles and who have concerns about silicone contamination should conduct their own testing to ensure they are suitable for their application(s). In what ways can I dispose of TYCHEM® 4000 garments ? If not contaminated, TYCHEM® 4000 garments may be landfilled or incinerated in accordance with local regulations. Uncontaminated chemical protective garments may be incinerated in a facility that is capable of handling mixtures containing plastics. Likewise, an uncontaminated chemical protective garment may be buried in a facility that accepts plastic materials. TYCHEM® 4000 garments may contain several different materials; they are not suitable for recycling.

Contaminated garments that cannot be handled safely without protective equipment must be disposed of with other hazardous wastes, either through incineration or landfill per local regulations.

Before discarding, cut off a sleeve or a leg so the garments cannot be worn again as protective clothing. Do TYCHEM® 4000 products contain latex? As of January 2023, all DuPont Personal Protection products are manufactured under specifications that exclude components containing natural rubber latex. Tyvek® 500, Tyvek® 600 and Tyvek® 800 styles made before January 2023 contain natural rubber latex, which may cause allergic reactions in some sensitized individuals. Anyone who begins to exhibit an allergic response during the use of DuPont products should immediately cease using these products and should report it to DuPont at +1 (888) 439-2988 so that an investigation can be initiated. What determines if the garment is contaminated ? The decision on whether or not a garment has been contaminated is made by local managers responsible for PPE based on an analysis of the incident in which the garment was used. This analysis may include exposure time, chemicals involved, level of exposure, proximity to the actual release, tasks performed and environmental monitoring in the area in which the garment was worn. Garments that are damaged, altered or show signs of contamination, such as discoloration, odor, stiffening or cracks, should not be used. Where can I find a SDS (Safety Data Sheet) for TYCHEM® 4000 garments? Safety Data Sheets (SDS) are written in accordance with applicable federal regulations, 29 CFR 1910.1200, to communicate health and safety data on usage and handling of hazardous chemicals. Under this regulation, DuPont™ Tyvek®, ProShield®, and Tychem® materials and garments are defined as articles, not chemicals, and the SDS and labeling requirements in that standard do not apply. Permeation The concentration of my hazard is LOWER than what is listed in the "Search Hazards" box. What should I do? If the temperature of your hazard is LOWER than the hazard listed in the hazard search box, go ahead and select the higher temperature hazard as long as the physical phase (solid, liquid or gas/vapor) is the same. Because chemical hazards become more aggressive with increasing temperatures, selecting a higher temperature chemical hazard will lead to a more conservative result.
What are the donning and doffing instructions for TYCHEM® 4000 coveralls? Please refer to the Section on Donning and Doffing Non-Encapsulating Garments in the Tychem® User Manual - Non-Encapsulated. Is it possible to wash and re-use TYCHEM® 4000 garments? DuPont does not recommend washing contaminated TYCHEM® 4000 garments for re-use. These garments are designed for limited-use. They can be worn until damaged, altered or contaminated. However, if the garments have not been contaminated, they can be cleaned for hygienic purposes and re-used. Please refer to the section on Decontamination and Cleaning in the Tychem® User Manual - Encapsulated for more information. What is the shelf life of TYCHEM® 4000 garments? Tychem® garments may be used for 5 years from the date of manufacture as long as all of the following conditions are met:

  1. The garment has been stored properly (view storage conditions)
  2. The garment has not been damaged, altered or contaminated
  3. The garment passes a full visual inspection (view garment inspection instructions)

Permeation The concentration of my hazard is HIGHER than what is listed in the "Search Hazards" box. What should I do? If the concentration of your hazard is HIGHER than the hazard concentration listed in the hazard search box, you can NOT use the data for the lower concentration hazard. This data will not give you an accurate assessment of suitable garments. Please Contact Us for assistance.

DUPONT™ SAFESPEC™ Terms of Use

Product Selector Agreement

The following information must be read and accepted by the user before proceeding.

The DuPont™ SafeSPEC™ Product Selector Tool  (“Tool”) is intended to assist in choosing protective clothing styles for particular applications and does not replace the judgment of a qualified safety professional or industrial hygienist. Additional personal protective equipment (“PPE”), such as but not limited to: respiratory, eye, head, foot, and hand protection, may be required. Supplying the proper hazard/chemical and exposure information for your hazard scenario is critical in order to obtain suggestions of possible garment options for your consideration. Inaccurate information could result in improper suggestions. Since there are other factors involved which could affect the final PPE decision and may not be considered in this Tool, the final decision on protective clothing selection is the responsibility of the buyer, safety professional, industrial hygienist and end-user. DuPont de Nemours, Inc. or its affiliates DISCLAIM ANY RESPONSIBILITY OR LIABILITY FOR ANY INFORMATION OR SUGGESTIONS PROVIDED BY THE TOOL OR THE USE THEREOF.

WARNING / CAUTION

There are uses, environments and chemicals for which any garment will be unsuitable. It is the responsibility of the user to review available data and verify that the garment selected is appropriate for the intended use and meets all specified government and industry standards.

Search by :

1 Choose Hazards

1 Enter
Chemicals

2 View Permeation Data

2 View
Data

3 View Matching Products

3 View
Products

Step 1 of 3

You may enter from one to five chemicals or other hazards that may be present in your working environment. Our tool will find the best product match for the combined hazards. Enter a single chemical or hazard if you wish to find the best possible product match for that one hazard.

Chemical or Other Hazard Name

Enter at least 3 characters and select hazard from list.

or

CAS Number

Synonyms, Class and Sub-Class information

Hazard Concentration information

close_icon

Please read following

Read FAQ if your Hazard concentration is lower than the tested concentration Read FAQ if your Hazard concentration is higher than the tested concentration close_icon

Need Help?

close_icon

1 Choose Hazards

1 Enter
Chemicals

2 View Permeation Data

2 View
Data

3 View Matching Products

3 View
Products

Step 2 of 3

CHEMICAL COMPARISON

The table below shows the Normalized Breakthrough times of fabrics for the hazards selected. (Testing Details) You can find specific garments that protect against these hazards by clicking the 'Next' button below.

Done

btAct

Done

btAct

Done

<< BACK TO CHEMICAL LIST

All

1 Choose Hazards

1 Enter
Chemicals

2 View Permeation Data

2 View
Data

3 View Matching Products

3 View
Products

Step 3 of 3

Exposure

close_icon

Please provide a response to all exposure questions before proceeding.

Flammable Environments

close_icon

WARNING

If any of the following apply:

STOP USING THIS TOOL. Please consider fire fighter PPE (personal protective equipment). Read more.

If none of these conditions apply but FR clothing is required in your working environment, close this box and proceed to the next question. Only fabrics that provide both chemical resistance to the hazards you have listed and protection during escape from a flash fire will be considered for your hazard scenario.

1 Choose Hazards

1 Enter
Chemicals

2 View Permeation Data

2 View
Data

3 View Matching Products

3 View
Products

step3of3

Is Suitable For Hazard Scenario

Is Not Suitable For Hazard Scenario

Compare All

rel-car-left-arrwprod-right-arrow

Matching Products (0)

Your hazard scenario did not produce any results. May we suggest:

If you still need help, please Contact Us.

rel-car-left-arrwprod-right-arrow

For a general fabric overview, please view our

Hazards Matrix

SELECT FROM SAVED SCENARIO

Please select the Scenario you have saved for the

Saved Scenario for

Is Suitable For Hazard Scenario

Is Not Suitable For Hazard Scenario

Compare All

rel-car-left-arrwprod-right-arrow

For a general fabric overview, please view our

Hazards Matrix rel-car-left-arrwprod-right-arrowHover over image to zoom

Full Part Number
SL127BWHxx0012yy (xx=size;yy=option code)  Help
Fabric/Materials
TYCHEM® 4000
Design
Coverall w/ Hood, Elastic Wrists and Ankles
Seam
Bound
Color
White
Quantity/Box
12 per case
Sizes
MD, LG, XL, 2X, 3X, 4X, 5X, 6X, 7X
Option Codes
00

Technical Data Sheet

image DuPont™ Tychem® 4000

DuPont™ Tychem® 4000 Hooded Coverall. Offers rugged, durable protection against a wide range of chemicals. White coverall features a standard fit hood, elastic wrists and ankles, a storm flap with adhesive closure, taped seams, and a pin lock slider zipper pull. Suitable for a variety of applications, including hazardous remediation, nuclear environments, waste management, and chemical handling.

Learn More image DuPont™ Tychem® 4000

DuPont™ Tychem® 4000 Hooded Coverall with Attached Socks. Offers rugged, durable protection against a wide range of chemicals. White coverall features a respirator fit hood, elastic wrists, attached socks with outer boot flaps, a storm flap with adhesive closure, a semi-auto locking slider zipper pull, and taped seams. Suitable for a variety of applications, including hazardous remediation, nuclear environments, waste management, and chemical handling.

Learn More image DuPont™ Tychem® 4000

DuPont™ Tychem® 4000 Bib Apron. Offers rugged, durable frontal protection against a wide range of chemicals. White, 28" x 43" bib apron features a neck loop, ties at the waist, and taped seams. Suitable for a variety of applications, including hazardous remediation, nuclear environments, waste management, and chemical handling.

Learn More

FEATURES & PRODUCT DETAILS

DuPont™ Tychem® 4000 delivers effective protection against a range of chemical environments. Tychem® 4000 utilizes a chemical barrier film laminated to a Tyvek® substrate to provide a rugged and durable fabric that resists abrasion. Tychem® 4000 fabric provides at least 30 minutes of protection against >124 chemical challenges. Typical applications: chemical mixing, hazardous remediation, emergency medical response, paint spraying, and nuclear environments.

AVAILABLE OPTIONS

00
Standard
MD,LG,XL,2X,3X,4X,5X,6X,7X
SL127BWHxx001200

SPECIFICATIONS

sample_image

FINISHED DIMENSIONS

MD
33 3/4
24 1/4
27 1/2
35 1/4 - 38 3/4
5'3" - 5'7"
LG
35
25 3/4
28 1/2
38 1/4 - 41 3/4
5'5" - 5'9"
XL
36 1/2
27 1/4
29
41 1/4 - 44 3/4
5'8" - 6'2"
2X
38 1/4
28 3/4
30
44 1/4 - 47 3/4
6'0" - 6'4"
3X
38 1/2
30 1/4
31
47 1/4 - 50 3/4
6'2" - 6'4"
4X
39 1/2
32
32
50 3/4 - 54 1/4
6'4" - 6'7"
5X
40 1/2
33 1/2
33
53 3/4 - 57 1/4
6'7" - 6'10"
6X
41 1/2
35 1/2
34
57 3/4 - 61 1/4
6'9" - 7'1"
7X
42 1/2
37
35
60 3/4 - 64 1/4
7'0" - 7'4"

ADDITIONAL EQUIPMENT NEEDED

FABRIC & CHEMICAL RESISTANCE DATA

Physical Properties

Data relating to mechanical performance of the fabrics used in DuPont chemical protective clothing, listed for the selected garment according to the test methods and relevant European standard, if applicable. Such properties, including abrasion and flex-cracking resistance, tensile strength and puncture resistance can help in the assessment of protective performance.

Featured resources Download Permeation Guide

Thickness
ASTM D1777
12 mils
Basis Weight
ASTM D3776
3.6 oz/yd2
Burst Strength - Mullen
ASTM D3786
71 psi
Breaking Strength - Grab (MD)
ASTM D5034
44 lbf
Breaking Strength - Grab (CD)
ASTM D5034
48 lbf
Wearing Apparel Flammability
16 CFR 1610 Help
Class 1

CHEMICAL RESISTANCE

2-(2-Ethoxyethoxy) ethanol
111-90-0
Liquid
>480
2-Methyl-4-isothiazolin-3-one (20%)
2682-20-4
Liquid
>480
Acetic acid (>95%)
64-19-7
Liquid
>480
Acetic acid 2 ethoxy ethyl ester
111-15-9
Liquid
116*/238
Acetic acid 2 methoxy ethyl ester
110-49-6
Liquid
>480
Acetic acid ethenyl ester
108-05-4
Liquid
24
Acetic acid ethyl ester
141-78-6
Liquid
imm
Acetic anhydride
108-24-7
Liquid
12*/48
Acetic chloride
75-36-5
Liquid
39*/63
Acetone
67-64-1
Liquid
13
Acetonitrile
75-05-8
Liquid
60
Acetyl chloride
75-36-5
Liquid
39*/63
Acroleic acid
79-10-7
Liquid
>480
Acrolein (90%)
107-02-8
Liquid
24
Acrylamide (50%)
79-06-1
Liquid
>480
Acrylic acid
79-10-7
Liquid
>480
Acrylic acid n-butyl ester
141-32-2
Liquid
>480
Acrylicamide (50%)
79-06-1
Liquid
>480
Acrylonitrile
107-13-1
Liquid
36*/48
Acryloyl Chloride
814-68-6
Liquid
imm
Allyl alcohol
107-18-6
Liquid
>480
Amino 3,4-dichlorobenzene, 1- (70 °C, molten)
95-76-1
Liquid
imm
Amino benzene
62-53-3
Liquid
>480
Amino diphenyl, 4- (1 mg/ml in Methanol)
92-67-1
Liquid
>480
Amino ethylethanolamine
111-41-1
Liquid
imm
Amino ethylethanolamine (60%)
111-41-1
Liquid
>480
Amino ethylpiperazine
140-31-8
Liquid
>480
Amino pyridine, 2- (sat)
504-29-0
Liquid
>480
Ammonia (gaseous)
7664-41-7
Vapor
26
Ammonium hydroxide (2-3% in Householdcleaner)
1336-21-6
Liquid
>480
Ammonium hydroxide (32%)
1336-21-6
Liquid
55
Aniline
62-53-3
Liquid
>480
Antimony pentachloride
7647-18-9
Liquid
>480
Benzenamine
62-53-3
Liquid
>480
Benzene
71-43-2
Liquid
imm
Benzisothiazol 1,2- (20%)
2634-33-5
Liquid
>480
Benzyl alcohol
100-51-6
Liquid
>480
Bis (4-(2,3-epoxypropoxy)phenyl)propane (80%)
1675-54-3
Liquid
>480
Bis phenol A diglycidyl ether (80%)
1675-54-3
Liquid
>480
Black Liquor (mix)
mix
Liquid
>480
Bromo methane
74-83-9
Vapor
>480
Butadiene, 1,3- (gaseous)
106-99-0
Vapor
>480
Butanal, n-
123-72-8
Liquid
41
Butanol, 1-
71-36-3
Liquid
>480
Butanol, n-
71-36-3
Liquid
>480
Butanone
78-93-3
Liquid
18
Butanone oxime, 2-
96-29-7
Liquid
>480
Butenal, 2-
123-73-9
Liquid
34
Butoxy ethanol, 2-
111-76-2
Liquid
>480
Butyl acrylate, n-
141-32-2
Liquid
>480
Butyl alcohol, n-
71-36-3
Liquid
>480
Butyraldehyde, n-
123-72-8
Liquid
41
Carbon disulfide
75-15-0
Liquid
imm
Carburant n° 2
68476-30-2
Liquid
>480
Caustic ammonia (2-3% in Householdcleaner)
1336-21-6
Liquid
>480
Caustic ammonia (32%)
1336-21-6
Liquid
55
Caustic soda (50%)
1310-73-2
Liquid
>480
Cellosolve acetate
110-80-5
Liquid
>480
Chemguard S-764P14A
mix
Liquid
>480
Chemidize 727 ND (mix)
mix
Liquid
>480
Chlorine (gaseous)
7782-50-5
Vapor
>480
Chloro 1-methylbenzene, 2-
95-49-8
Liquid
13
Chloro 2,3-epoxy propane, 1-
106-89-8
Liquid
15
Chloro acetic acid (80%)
79-11-8
Liquid
>480
Chloro acetone (95%)
78-95-5
Liquid
258
Chloro acetyl chloride
79-04-9
Liquid
120
Chloro aniline, p- (70 °C, molten)
106-47-8
Liquid
imm
Chloro benzenamine, 4- (70 °C, molten)
106-47-8
Liquid
imm
Chloro ethene
75-01-4
Vapor
>480
Chloro propan-2-one, 1- (95%)
78-95-5
Liquid
258
Chloro toluene, o-
95-49-8
Liquid
13
Chloroform
67-66-3
Liquid
imm
Chlorsulfonic acid
7790-94-5
Liquid
>480
Chromic acid (CrO3) (44.9%)
1333-82-0
Liquid
>480
Cresol o-
95-48-7
Liquid
>480
Cresols, mixed isomers
1319-77-3
Liquid
100
Cresylic acid
1319-77-3
Liquid
100
Croton aldehyde
123-73-9
Liquid
34
Crude oil
8002-05-9
Liquid
>480
Crude oil, California
8002-05-9
Liquid
>480
Cyanoethylene
107-13-1
Liquid
36*/48
Cyanomethane
75-05-8
Liquid
60
Cyclo hexanone
108-94-1
Liquid
136
Cyclo hexyl isocanyte
3173-53-3
Liquid
36*/54
Diaminoethane, 1,2-
107-15-3
Liquid
>480
Dichlorbenzen, 1,2-
95-50-1
Liquid
76
Dichlorbenzen, 1,3-
541-73-1
Liquid
45
Dichlorbenzen, 1,4- (50% in Ethanol)
106-46-7
Liquid
>480
Dichlorethane, 1.2.-
107-06-2
Liquid
imm
Dichloro -4,4'-methylenedianiline, 2,2'- (sat in Methanol)
101-14-4
Liquid
>480
Dichloro aniline, 3,4- (70 °C, molten)
95-76-1
Liquid
imm
Dichloro methane
75-09-2
Liquid
imm
Diesel Fuel Grade D-2
mix
Liquid
>480
Diethyl amine
109-89-7
Liquid
15
Diethyl aniline crude
91-66-7
Liquid
>480
Diethyl benzene (95%)
25340-17-4
Liquid
31
Diethyl ethanamine, N,N-
121-44-8
Liquid
12*/22
Diethyl ether
60-29-7
Liquid
imm
Diethyl m-toluidine, N,N-
91-67-8
Liquid
>480
Diethylene imide oxide
110-91-8
Liquid
158
Diethylene triamine
111-40-0
Liquid
imm*/321
Dimethyl Carbonate (DMC)
616-38-6
Liquid
35
Dimethyl acetamide, N,N-
127-19-5
Liquid
96
Dimethyl dichlorosilane
75-78-5
Liquid
46
Dimethyl formamide, N,N-
68-12-2
Liquid
90
Dimethyl hydrazine, N,N-
57-14-7
Liquid
13
Dimethyl ketal
67-64-1
Liquid
13
Dimethyl ketone
67-64-1
Liquid
13
Dimethyl maleate
624-48-6
Liquid
>480
Dimethyl sulfate
77-78-1
Liquid
>480
Diphenyl methane diisocyanate, 4,4'- (50 °C, molten)
101-68-8
Liquid
>480
Disodium sulfide (60% (slurry))
1313-82-2
Liquid
>480
Epichlorohydrin
106-89-8
Liquid
15
Epoxy ethane (gaseous)
75-21-8
Vapor
imm
Ethane 1,2-diol
107-21-1
Liquid
>480
Ethane diol dipropanoate, 1,2-
123-73-9
Liquid
34
Ethane nitrile
75-05-8
Liquid
60
Ethane thiol
75-08-1
Liquid
imm
Ethanol
64-17-5
Liquid
>480
Ethanoyl chloride
75-36-5
Liquid
39*/63
Ethoxy ethanol, 2-
110-80-5
Liquid
>480
Ethoxy ethylacetat
111-15-9
Liquid
116*/238
Ethyl Cellosolve®
110-80-5
Liquid
>480
Ethyl acetate
141-78-6
Liquid
imm
Ethyl alcohol
64-17-5
Liquid
>480
Ethyl benzene
100-41-4
Liquid
imm
Ethyl ethanamine, N-
109-89-7
Liquid
15
Ethyl ether
60-29-7
Liquid
imm
Ethyl glycol acetate
111-15-9
Liquid
116*/238
Ethyl mercaptan
75-08-1
Liquid
imm
Ethyl methyl carbonate (EMC)
623-53-0
Liquid
25
Ethyl nitrile
75-05-8
Liquid
60
Ethylene Carbonate solution (60%)
96-49-1
Liquid
>480
Ethylene carboxylic acid
79-10-7
Liquid
>480
Ethylene diamine
107-15-3
Liquid
>480
Ethylene dichloride
107-06-2
Liquid
imm
Ethylene glycol
107-21-1
Liquid
>480
Ethylene glycol mono ethyl ether acetate
111-15-9
Liquid
116*/238
Ethylene glycol monobutyl ether
111-76-2
Liquid
>480
Ethylene glycol monoethyl ether
110-80-5
Liquid
>480
Ethylene glycol monomethyl ether
109-86-4
Liquid
>480
Ethylene glycol monomethyl ether acetate
110-49-6
Liquid
>480
Ethylene oxide (gaseous)
75-21-8
Vapor
imm
Ethylene tetrachloride
127-18-4
Liquid
imm
Ethylene trichloride
79-01-6
Liquid
imm
Ferric (III) chloride (50%)
7705-08-0
Liquid
>480
Fluorobenzene
462-06-6
Liquid
imm
Fluoroboric acid (48-50%)
16872-11-0
Liquid
>480
Fluorosilicic acid (33-35%)
16961-83-4
Liquid
>480
Formaldehyde (37%)
50-00-0
Liquid
>480
Formalin (37% (10-15% Methanol))
50-00-0
Liquid
>480
Formalin (37%)
50-00-0
Liquid
>480
Formic acid (88%)
64-18-6
Liquid
>480
Fuel-oil no 2
68476-30-2
Liquid
>480
Furaldehyde, 2-
98-01-1
Liquid
198*/227
Furfural
98-01-1
Liquid
198*/227
Gasoline, unleaded
86290-81-5
Liquid
imm
Gasoline, unleaded E10 (87 Octane)
308066-70-8
Liquid
imm
Glutaral (50%)
111-30-8
Liquid
>480
Glutaraldehyde (50%)
111-30-8
Liquid
>480
Glycol alcohol
107-21-1
Liquid
>480
Green Liquor (mix)
mix
Liquid
>480
Hexamethyl disilazane
999-97-3
Liquid
>480
Hexamethyl disilazane, 1,1,1,3,3,3-
999-97-3
Liquid
>480
Hexamethylene diamine (50 °C, molten)
124-09-4
Liquid
80
Hexamethylene diisocyanate
822-06-0
Liquid
>480
Hexane, n-
110-54-3
Liquid
imm
Hexanone
108-94-1
Liquid
136
Hydrazine
302-01-2
Liquid
>480
Hydriodic acid (47%)
10034-85-2
Liquid
>480
Hydrochloric acid (37%)
7647-01-0
Liquid
>480
Hydrofluoric acid (48-51%)
7664-39-3
Liquid
>480
Hydrofluoric acid (70%)
7664-39-3
Liquid
143
Hydrogen chloride (gaseous)
7647-01-0
Vapor
>480
Hydrogen fluoride (20-27 °C, gaseous)
7664-39-3
Vapor
93*/134
Hydrogen peroxide (30%)
7722-84-1
Liquid
>480
Hydroxy 2-nitrobenzene, 1- (70 °C, molten)
88-75-5
Liquid
imm
Hydroxy toluene
100-51-6
Liquid
>480
Hydroxy toluene, o-
95-48-7
Liquid
>480
Iodine
7553-56-2
Solid
>480
Iodomethane
74-88-4
Liquid
imm
Isoamyl alcohol
123-51-3
Liquid
>480
Isopropanol
67-63-0
Liquid
>480
Isopropanol (70%)
67-63-0
Liquid
>480
Isopropyl alcohol
67-63-0
Liquid
>480
Isopropyl alcohol (70%)
67-63-0
Liquid
>480
Isopropylidenediphenol diglycidyl ether, 4,4'- (80%)
1675-54-3
Liquid
>480
JP-4 Jet Fuel
50815-00-4
Liquid
imm
JP-8 Jet Fuel
94114-58-6
Liquid
39*/67
Kerosene
8008-20-6
Liquid
69
Ketone propane
67-64-1
Liquid
13
Lewisite (L), MIL-STD-282 (10 g/m2)
541-25-3
Liquid
>3608
Lithium Hexafluorophosphate (sat.)
21324-40-3
Liquid
>480
MEK
78-93-3
Liquid
18
Maleic anhydride (66 °C, molten)
108-31-6
Liquid
13
Mercuric II chloride (sat)
7487-94-7
Liquid
>480
Mercury
7439-97-6
Liquid
>480
Methanesulphonic acid (70%)
75-75-2
Liquid
>480
Methanol
67-56-1
Liquid
>480
Methoxy 2-methylpropane, 2-
1634-04-4
Liquid
>480
Methoxy ethanol, 2
109-86-4
Liquid
>480
Methoxy ethylacetate, 2-
110-49-6
Liquid
>480
Methyl 2-methyl-2-propenoate
80-62-6
Liquid
23
Methyl 2-pyrrolidone, N-
872-50-4
Liquid
101
Methyl Ethyl Ketone Peroxide (35%)
1338-23-4
Liquid
>480
Methyl acetyl
67-64-1
Liquid
13
Methyl acrolein
123-73-9
Liquid
34
Methyl aniline, o-
95-53-4
Liquid
>480
Methyl benzol
108-88-3
Liquid
imm
Methyl bromide
74-83-9
Vapor
>480
Methyl butan-1-ol, 3-
123-51-3
Liquid
>480
Methyl chloride (-70 °C, liquid)
74-83-9
Vapor
>480
Methyl chloride (gaseous)
74-87-3
Vapor
>480
Methyl cyanide
75-05-8
Liquid
60
Methyl ethyl ketone
78-93-3
Liquid
18
Methyl ethyl ketoxime
96-29-7
Liquid
>480
Methyl iodide
74-88-4
Liquid
imm
Methyl isocyanate
624-83-9
Liquid
imm
Methyl ketone
67-64-1
Liquid
13
Methyl methacrylate
80-62-6
Liquid
23
Methyl phenols
1319-77-3
Liquid
100
Methyl salicylate
119-36-8
Liquid
>480
Methyl tert-butyl ether
1634-04-4
Liquid
>480
Methylen Isocyclohexylamine, 4,4- (50 °C, molten)
1761-71-3
Liquid
>480
Methylene bis(2-Chloroaniline), 4,4- (sat in Methanol)
101-14-4
Liquid
>480
Methylene chloride
75-09-2
Liquid
imm
Methylene diphenyl diisocyanate, 4,4'- (50 °C, molten)
101-68-8
Liquid
>480
Mineral oil
8012-95-1
Liquid
>480
Mineral spirit
64475-85-0
Liquid
190
Morpholine
110-91-8
Liquid
158
Naphthalene (25% in Diethylene glycol dimethylether)
91-20-3
Liquid
79
Nitric acid (70%)
7697-37-2
Liquid
>480
Nitro benzene
98-95-3
Liquid
59
Nitro phenol, o- (70 °C, molten)
88-75-5
Liquid
imm
Nitro toluene, 2-
88-72-2
Liquid
95
Nitrogen Dioxide (liquid)
10102-44-0
Liquid
>480
Norflurane
811-97-2
Vapor
>480
Oleum (20% free SO3)
8014-95-7
Liquid
>480
Oleum (30% free SO3)
8014-95-7
Liquid
>480
PCB 1254 (50% in Mineral Oil)
11097-69-1
Liquid
>480
PCB 1254 (90%)
11097-69-1
Liquid
>480
Pentachloroantimony
7647-18-9
Liquid
>480
Pentanedial, 1,5- (50%)
111-30-8
Liquid
>480
Peracetic Acid (32%)
79-21-0
Liquid
272
Phenethylene
100-42-5
Liquid
16
Phenol (45 °C, molten)
108-95-2
Liquid
44
Phenol (60 °C, molten)
108-95-2
Liquid
imm
Phenol (85%)
108-95-2
Liquid
>480
Phenyl amine
62-53-3
Liquid
>480
Phenyl ethane
100-41-4
Liquid
imm
Phenyl ethanol, 1-
98-85-1
Liquid
>480
Phenyl glycidyl ether
122-60-1
Liquid
>480
Phenyl trichlorosilane
98-13-5
Liquid
>480
Phosphoric acid (85%)
7664-38-2
Liquid
>480
Phosphorus trichloride
7719-12-2
Liquid
imm
Pimelic ketone
108-94-1
Liquid
136
Polymethylene polyphenyle isocyanate (p-MDI)
9016-87-9
Liquid
>480
Potassium acetate (sat)
127-08-2
Liquid
>480
Potassium chromate (sat)
7789-00-6
Liquid
>480
Potassium hydroxide (45%)
1310-58-3
Liquid
>480
Prop-2-en-1-al (90%)
107-02-8
Liquid
24
Propan -2-ol
67-63-0
Liquid
>480
Propan -2-ol (70%)
67-63-0
Liquid
>480
Propan -2-one
67-64-1
Liquid
13
Propen 1-ol, 2-
107-18-6
Liquid
>480
Propenamide (50%)
79-06-1
Liquid
>480
Propene acid
79-10-7
Liquid
>480
Propenenitrile, 2-
107-13-1
Liquid
36*/48
Propenoic acid butyl ester, 2-
141-32-2
Liquid
>480
Propenoic acid nitrile
107-13-1
Liquid
36*/48
Propyl bromide, n-
106-94-5
Liquid
12
Propylene aldehyde
123-73-9
Liquid
34
Pyridine
110-86-1
Liquid
31
Pyroacetic ether
67-64-1
Liquid
13
Sarin (GB), MIL-STD-282 (10 g/m2)
107-44-8
Liquid
>4808
Silicon tetrachloride
10026-04-7
Liquid
35
Skydrol 4D
mix
Liquid
>480
Skydrol 5
mix
Liquid
>480
Skydrol PE-5
mix
Liquid
>480
Sodium bisulphite (38-40%)
7631-90-5
Liquid
>480
Sodium cyanide (sat)
143-33-9
Liquid
>480
Sodium fluoride (sat)
7681-49-4
Liquid
>480
Sodium hydroxide (50%)
1310-73-2
Liquid
>480
Sodium hypochlorite (15%)
7681-52-9
Liquid
>480
Sodium metabisulphite (38%)
7681-57-4
Liquid
>480
Spectracide® (50% Malathion, 44% Aromatic Solvent)
mix
Liquid
>480
Spiritus
64-17-5
Liquid
>480
Styrene
100-42-5
Liquid
16
Sulfur Mustard (HD), MIL-STD-282 (10 g/m2)
505-60-2
Liquid
>4808
Sulfur dioxide
7446-09-5
Vapor
>480
Sulfuric acid (>95%)
7664-93-9
Liquid
>480
Sulfuric acid dimethyl ester
77-78-1
Liquid
>480
Sulfuric acid fuming (20% free SO3)
8014-95-7
Liquid
>480
Sulfuric acid fuming (30% free SO3)
8014-95-7
Liquid
>480
Tetrachloro ethane, 1,1,2,2,-
79-34-5
Liquid
25
Tetrachloro ethylene, 1,1,2,2-
127-18-4
Liquid
imm
Tetraethyl ammonium hydroxide (35%)
77-98-5
Liquid
>480
Tetraethylene pentamine
112-57-2
Liquid
>480
Tetrafluoroethane, 1,1,1,2-
811-97-2
Vapor
>480
Tetrahydrofuran
109-99-9
Liquid
imm
Tetramethyl ammonium hydroxide (25%)
75-59-2
Liquid
>480
Thioalkohol
75-08-1
Liquid
imm
Titan(IV) chloride
7550-45-0
Liquid
imm
Titanium tetrachloride
7550-45-0
Liquid
imm
Toluene
108-88-3
Liquid
imm
Toluene diisocyanate, 2,4-
584-84-9
Liquid
>480
Toluene diisocyanate, 2,4- (80%)
584-84-9
Liquid
>480
Toluidine, m-
108-44-1
Liquid
>480
Toluidine, o-
95-53-4
Liquid
>480
Trichlor vinylsilane
75-94-5
Liquid
100
Trichloro benzene, 1,2,4-
120-82-1
Liquid
87
Trichloro ethanol, 2,2,2-
115-20-8
Liquid
>480
Trichloro ethylene
79-01-6
Liquid
imm
Trichloro methane
67-66-3
Liquid
imm
Trichloro phenylsilane
98-13-5
Liquid
>480
Trichloro silane
10025-78-2
Liquid
60
Triethyl amine
121-44-8
Liquid
12*/22
Triethylentetramine (60%)
112-24-3
Liquid
>480
Trifluoro acetic acid
76-05-1
Liquid
>480
Trifluoro methansulfonic acid
1493-13-6
Liquid
>480
Trimethyl phosphite
121-45-9
Liquid
210
VM & P Naphtha
8030-30-6
Liquid
imm
VX Nerve Agent, MIL-STD-282 (10 g/m2)
50782-69-9
Liquid
>4808
Vinyl acetate
108-05-4
Liquid
24
Vinyl benzol
100-42-5
Liquid
16
Vinyl carbinol
107-18-6
Liquid
>480
Vinyl chloride
75-01-4
Vapor
>480
Vinyl cyanide
107-13-1
Liquid
36*/48
Vinyl ethylene (gaseous)
106-99-0
Vapor
>480
Vinyl magnesium chloride (15% in Tetrahydrofuran)
3536-96-7
Liquid
imm
Vinyl pyridine, 4-
100-43-6
Liquid
15
White Liquor
mix
Liquid
>480

Important Notehelp

SPECIAL WARNINGS

View by: View all resources ✕ ✕ To access secured content from DuPont Please Sign In or Sign Up below Sign In New User ? Sign Up