Tyvek / DuPont™ Tychem® 2000

QC125S YL

DuPont™ Tychem® 2000

DuPont™ Tychem® 2000 Coverall. Offers lightweight and durable protection against a variety of industrial chemical threats. Yellow coverall features a collar, elastic wrists and ankles, a storm flap, serged seams, and a pin lock slider zipper pull. Suitable for light liquid splash protection in industries such as chemical processing, petroleum refining, pharmaceutical manufacturing, and food processing.

Share

Frequently Asked Questions

QC125S YL

DuPont™ Tychem® 2000

How should TYCHEM® 2000 garments be stored? Store TYCHEM® 2000 garments in a cool, dark, dry location free of dirt and insects. Sunlight, ozone, high temperatures (>120° F ; 49° C), vehicle exhaust fumes, compression under heavy weights and sharp edges or projections are some conditions known to degrade the materials in these garments.

Store TYCHEM® 2000 garments in boxes, in bags or on hangers. Never step on protective garments. Never place or store heavy objects on top of protective garments. What is the ambient working temperature range for TYCHEM® 2000 garments? Tychem® garments can be worn in ambient temperatures of -13°F (-25°C) to 165°F (74°C).
In colder environments, Tychem® garments can become stiff. If cold enough, the fabric may even become brittle. Please be aware that the heat stress of the wearer becomes a greater concern in higher ambient temperatures. At higher temperatures, chemical hazards can become more aggressive. Breakthrough times and permeation rates may change at higher temperatures. The published permeation data per ASTM F739 is performed at ambient temperatures (approximately 72-81° F ; 22-27° C).

Caution: Tychem® fabrics offer little or no thermal insulation to protect the wearer's skin from prolonged exposure to hot or cold. Do TYCHEM® 2000 garments meet ANSI/ISEA 101 sizing standards? Yes. DuPont™ TYCHEM® 2000 coveralls either meet or exceed ANSI/ISEA 101 sizing standards. For specific sizing dimensions on a particular DuPont garment, please view the Product Details tab for that garment. Can TYCHEM® 2000 garments be worn in cleanroom applications? TYCHEM® 2000 garments have not been designed for controlled environment applications. DuPont offers a full line of garments that have been specially manufactured, processed and packaged for use in controlled environment applications. Please see our complete line of controlled environment products at www.safespeccleanroom.dupont.com. Permeation The concentration of my hazard is HIGHER than what is listed in the "Search Hazards" box. What should I do? If the concentration of your hazard is HIGHER than the hazard concentration listed in the hazard search box, you can NOT use the data for the lower concentration hazard. This data will not give you an accurate assessment of suitable garments. Please Contact Us for assistance. Are TYCHEM® 2000 garments flame resistant or flame retardant (FR)? Other than Tychem® 6000 FR, Tychem® chemical protective garments will ignite and continue to burn.

Wearing garments made of Nomex® or any other flame-resistant fabric under Tychem® garments, other than Tychem® 6000 FR, will not reduce burn injury during a fire or electric arc exposure. Other than Tychem® 6000 FR, Tychem® garments will burn and possibly melt when exposed to a fire or electric arc flash; this may increase burn injuries even when worn over garments made of Nomex® or any other flame-resistant fabric.

And because Tychem® garments melt, except for Tychem® 6000 FR do not wear Tychem® garments under a garment made of Nomex® or any other flame resistant fabric if the potential for fire or electric arc flash exists.

Do not knowingly enter an environment in which the concentration of flammable gas is within flammable or explosive limits when wearing a Tychem® garment, including when wearing a Tychem® 6000 FR garment. Retreat immediately if you encounter such an environment while wearing any Tychem® garment, including Tychem® 6000 FR.

No Tychem® garment, including Tychem® 6000 FR,is intended for fire fighting activities, nor for protection from hot liquids, steam, molten metals, welding, or thermal radiation. Tychem® 6000 FR garments are designed and tested to help reduce injury during escape from a fire and to provide some protection from electric arcs. What determines if the garment is contaminated ? The decision on whether or not a garment has been contaminated is made by local managers responsible for PPE based on an analysis of the incident in which the garment was used. This analysis may include exposure time, chemicals involved, level of exposure, proximity to the actual release, tasks performed and environmental monitoring in the area in which the garment was worn. Garments that are damaged, altered or show signs of contamination, such as discoloration, odor, stiffening or cracks, should not be used. In what ways can I dispose of TYCHEM® 2000 garments ? If not contaminated, TYCHEM® 2000 garments may be landfilled or incinerated in accordance with local regulations. Uncontaminated chemical protective garments may be incinerated in a facility that is capable of handling mixtures containing plastics. Likewise, an uncontaminated chemical protective garment may be buried in a facility that accepts plastic materials. TYCHEM® 2000 garments may contain several different materials; they are not suitable for recycling.

Contaminated garments that cannot be handled safely without protective equipment must be disposed of with other hazardous wastes, either through incineration or landfill per local regulations.

Before discarding, cut off a sleeve or a leg so the garments cannot be worn again as protective clothing. Are TYCHEM® 2000 garments anti-static or static dissipative? The substrate used to make TYCHEM® 2000 garments is treated with a topical antistatic agent to help minimize static build up and reduce nuisance garment cling.

In situations where static dissipation level is a critical performance property, end-users should evaluate the performance of their entire ensemble as worn including outer garments, inner garments, footwear and other PPE. In order for any garment system to be static dissipative, it must be able to drain a charge buildup through proper grounding devices, such as, but not limited to, workstation grounding clips or static-dissipative floors.

Under certain conditions, such as cold and dry weather, it is possible that garments might build and discharge static electricity. Discharges are not normally dangerous except in situations where the generation of an electrical spark could ignite a flammable atmosphere or startle the wearer. When operating around flammable chemicals, take steps to eliminate potential static discharges. In these situations, suggested steps include, but not limited to, water spray, the use of an overcover, raising humidity level of the work area, use of a commercial, anti-static application coating, grounding straps on equipment and personnel, inherently static-dissipating under- and over-garments, and testing of the worker's static dissipation before entry into the classified area.

However, in the case of explosive or flammable atmospheres, even if steps are taken to manage static formation and dissipate static charge, the risk of severe injury remains if an uncontrolled or accidental ignition occurs. Do not wearTYCHEM® 2000 chemical protective garments in potentially flammable or explosive atmospheres. Do not knowingly enter an environment in which the concentration of flammable gas is within flammable or explosive limits while wearing a TYCHEM® 2000 garment. If you determine that you are in a potentially flammable or explosive environment, retreat immediately. Do TYCHEM® 2000 products contain latex? As of January 2023, all DuPont Personal Protection products are manufactured under specifications that exclude components containing natural rubber latex. Tyvek® 500, Tyvek® 600 and Tyvek® 800 styles made before January 2023 contain natural rubber latex, which may cause allergic reactions in some sensitized individuals. Anyone who begins to exhibit an allergic response during the use of DuPont products should immediately cease using these products and should report it to DuPont at +1 (888) 439-2988 so that an investigation can be initiated. Do TYCHEM® 2000 products contain silicone? All DuPont Personal Protection products are manufactured under specifications that do not contain silicone, with some exceptions. Tyvek® friction-coated shoe covers or Tyvek® garments with friction-coated shoe covers might contain silicone. This includes Tyvek® styles TY122, TY121, FC450 and FC454. Additionally, Tychem® 6000 AL styles TF630 and TF640T contain a silicone valve diaphragm. End users who are consuming these styles and who have concerns about silicone contamination should conduct their own testing to ensure they are suitable for their application(s). Permeation The concentration of my hazard is LOWER than what is listed in the "Search Hazards" box. What should I do? If the temperature of your hazard is LOWER than the hazard listed in the hazard search box, go ahead and select the higher temperature hazard as long as the physical phase (solid, liquid or gas/vapor) is the same. Because chemical hazards become more aggressive with increasing temperatures, selecting a higher temperature chemical hazard will lead to a more conservative result.
Where can I find a SDS (Safety Data Sheet) for TYCHEM® 2000 garments? Safety Data Sheets (SDS) are written in accordance with applicable federal regulations, 29 CFR 1910.1200, to communicate health and safety data on usage and handling of hazardous chemicals. Under this regulation, DuPont™ Tyvek®, ProShield®, and Tychem® materials and garments are defined as articles, not chemicals, and the SDS and labeling requirements in that standard do not apply. Is it possible to wash and re-use TYCHEM® 2000 garments? DuPont does not recommend washing contaminated TYCHEM® 2000 garments for re-use. These garments are designed for limited-use. They can be worn until damaged, altered or contaminated. However, if the garments have not been contaminated, they can be cleaned for hygienic purposes and re-used. Please refer to the section on Decontamination and Cleaning in the Tychem® User Manual - Encapsulated for more information. What are the donning and doffing instructions for TYCHEM® 2000 coveralls? Please refer to the Section on Donning and Doffing Non-Encapsulating Garments in the Tychem® User Manual - Non-Encapsulated. What is the shelf life of TYCHEM® 2000 garments? Tychem® garments may be used for 5 years from the date of manufacture as long as all of the following conditions are met:

  1. The garment has been stored properly (view storage conditions)
  2. The garment has not been damaged, altered or contaminated
  3. The garment passes a full visual inspection (view garment inspection instructions)

DUPONT™ SAFESPEC™ Terms of Use

Product Selector Agreement

The following information must be read and accepted by the user before proceeding.

The DuPont™ SafeSPEC™ Product Selector Tool  (“Tool”) is intended to assist in choosing protective clothing styles for particular applications and does not replace the judgment of a qualified safety professional or industrial hygienist. Additional personal protective equipment (“PPE”), such as but not limited to: respiratory, eye, head, foot, and hand protection, may be required. Supplying the proper hazard/chemical and exposure information for your hazard scenario is critical in order to obtain suggestions of possible garment options for your consideration. Inaccurate information could result in improper suggestions. Since there are other factors involved which could affect the final PPE decision and may not be considered in this Tool, the final decision on protective clothing selection is the responsibility of the buyer, safety professional, industrial hygienist and end-user. DuPont de Nemours, Inc. or its affiliates DISCLAIM ANY RESPONSIBILITY OR LIABILITY FOR ANY INFORMATION OR SUGGESTIONS PROVIDED BY THE TOOL OR THE USE THEREOF.

WARNING / CAUTION

There are uses, environments and chemicals for which any garment will be unsuitable. It is the responsibility of the user to review available data and verify that the garment selected is appropriate for the intended use and meets all specified government and industry standards.

Search by :

1 Choose Hazards

1 Enter
Chemicals

2 View Permeation Data

2 View
Data

3 View Matching Products

3 View
Products

Step 1 of 3

You may enter from one to five chemicals or other hazards that may be present in your working environment. Our tool will find the best product match for the combined hazards. Enter a single chemical or hazard if you wish to find the best possible product match for that one hazard.

Chemical or Other Hazard Name

Enter at least 3 characters and select hazard from list.

or

CAS Number

Synonyms, Class and Sub-Class information

Hazard Concentration information

close_icon

Please read following

Read FAQ if your Hazard concentration is lower than the tested concentration Read FAQ if your Hazard concentration is higher than the tested concentration close_icon

Need Help?

close_icon

1 Choose Hazards

1 Enter
Chemicals

2 View Permeation Data

2 View
Data

3 View Matching Products

3 View
Products

Step 2 of 3

CHEMICAL COMPARISON

The table below shows the Normalized Breakthrough times of fabrics for the hazards selected. (Testing Details) You can find specific garments that protect against these hazards by clicking the 'Next' button below.

Done

btAct

Done

btAct

Done

<< BACK TO CHEMICAL LIST

All

1 Choose Hazards

1 Enter
Chemicals

2 View Permeation Data

2 View
Data

3 View Matching Products

3 View
Products

Step 3 of 3

Exposure

close_icon

Please provide a response to all exposure questions before proceeding.

Flammable Environments

close_icon

WARNING

If any of the following apply:

STOP USING THIS TOOL. Please consider fire fighter PPE (personal protective equipment). Read more.

If none of these conditions apply but FR clothing is required in your working environment, close this box and proceed to the next question. Only fabrics that provide both chemical resistance to the hazards you have listed and protection during escape from a flash fire will be considered for your hazard scenario.

1 Choose Hazards

1 Enter
Chemicals

2 View Permeation Data

2 View
Data

3 View Matching Products

3 View
Products

step3of3

Is Suitable For Hazard Scenario

Is Not Suitable For Hazard Scenario

Compare All

rel-car-left-arrwprod-right-arrow

Matching Products (0)

Your hazard scenario did not produce any results. May we suggest:

If you still need help, please Contact Us.

rel-car-left-arrwprod-right-arrow

For a general fabric overview, please view our

Hazards Matrix

SELECT FROM SAVED SCENARIO

Please select the Scenario you have saved for the

Saved Scenario for

Is Suitable For Hazard Scenario

Is Not Suitable For Hazard Scenario

Compare All

rel-car-left-arrwprod-right-arrow

For a general fabric overview, please view our

Hazards Matrix rel-car-left-arrwprod-right-arrowHover over image to zoom

Full Part Number
QC125SYLxx0012yy (xx=size;yy=option code)  Help
Fabric/Materials
TYCHEM® 2000
Design
Coverall w/ Elastic Wrists and Ankles
Seam
Serged
Color
Yellow
Quantity/Box
12 per case
Sizes
MD, LG, XL, 2X, 3X, 4X, 5X, 6X, 7X
Option Codes
00,PI

Technical Data Sheet

image DuPont™ Tychem® 2000

DuPont™ Tychem® 2000 Coverall. Offers lightweight and durable protection against a variety of industrial chemical threats. Yellow coverall features a collar, elastic wrists and ankles, a storm flap with adhesive closure, bound seams, and a pin lock slider zipper pull. Suitable for light liquid splash protection in industries such as chemical processing, petroleum refining, pharmaceutical manufacturing, and food processing.

Learn More image DuPont™ Tychem® 2000

DuPont™ Tychem® 2000 Hooded Coverall. Offers lightweight and durable protection against a variety of industrial chemical threats. Yellow coverall features a standard fit hood, elastic wrists and ankles, a storm flap, serged seams, and a pin lock slider zipper pull. Suitable for light liquid splash protection in industries such as chemical processing, petroleum refining, pharmaceutical manufacturing, and food processing.

Learn More image DuPont™ Tychem® 2000

DuPont™ Tychem® 2000 Sleeve. Offers lightweight and durable protection against a variety of industrial chemical threats. Yellow, 18" long sleeve features elastic at both ends for arm protection. Suitable for light liquid splash protection in industries such as chemical processing, petroleum refining, pharmaceutical manufacturing, and food processing.

Learn More image DuPont™ Tychem® 4000

DuPont™ Tychem® 4000 Bib Apron. Offers rugged, durable frontal protection against a wide range of chemicals. White, 28" x 43" bib apron features a neck loop, ties at the waist, and taped seams. Suitable for a variety of applications, including hazardous remediation, nuclear environments, waste management, and chemical handling.

Learn More

FEATURES & PRODUCT DETAILS

A lightweight, and durable fabric, Tychem® 2000 fabric provides at least 30 minutes of protection against >40 chemical challenges. Tychem® 2000 is used for light splash protection in a variety of industrial environments, including petroleum refining, pulp and paper manufacturing, food processing, chemical processing, and pharmaceutical manufacturing.

AVAILABLE OPTIONS

00
Standard
MD,LG,XL,2X,3X,4X,5X,6X,7X
QC125SYLxx001200

SPECIFICATIONS

sample_image

FINISHED DIMENSIONS

MD
33 3/4
24 1/4
27 1/2
35 1/4 - 38 3/4
5'3" - 5'7"
LG
35
25 3/4
28 1/2
38 1/4 - 41 3/4
5'5" - 5'9"
XL
36 1/2
27 1/4
29
41 1/4 - 44 3/4
5'8" - 6'2"
2X
38 1/4
28 3/4
30
44 1/4 - 47 3/4
6'0" - 6'4"
3X
38 1/2
30 1/4
31
47 1/4 - 50 3/4
6'2" - 6'4"
4X
39 1/2
32
32
50 3/4 - 54 1/4
6'4" - 6'7"
5X
40 1/2
33 1/2
33
53 3/4 - 57 1/4
6'7" - 6'10"
6X
41 1/2
35 1/2
34
57 3/4 - 61 1/4
6'9" - 7'1"
7X
42 1/2
37
35
60 3/4 - 64 1/4
7'0" - 7'4"

ADDITIONAL EQUIPMENT NEEDED

FABRIC & CHEMICAL RESISTANCE DATA

Physical Properties

Data relating to mechanical performance of the fabrics used in DuPont chemical protective clothing, listed for the selected garment according to the test methods and relevant European standard, if applicable. Such properties, including abrasion and flex-cracking resistance, tensile strength and puncture resistance can help in the assessment of protective performance.

Featured resources Download Permeation Guide

Thickness
ASTM D1777
10 mils
Basis Weight
ASTM D3776
2.5 oz/yd2
Burst Strength - Mullen
ASTM D3786
68 psi
Tear Resistance - Trap Tear (MD)
ASTM D5587
6.4 lbf
Tear Resistance - Trap Tear (CD)
ASTM D5587
5 lbf
Breaking Strength - Grab (MD)
ASTM D5034
39 lbf
Breaking Strength - Grab (CD)
ASTM D5034
43 lbf
Wearing Apparel Flammability
16 CFR 1610 Help
Class 1

CHEMICAL RESISTANCE

2-Methyl-4-isothiazolin-3-one (20%)
2682-20-4
Liquid
>480
Acetic acid (>95%)
64-19-7
Liquid
imm
Acetic acid ethyl ester
141-78-6
Liquid
imm
Acetone
67-64-1
Liquid
imm
Acetonitrile
75-05-8
Liquid
imm
Acroleic acid
79-10-7
Liquid
imm
Acrylic acid
79-10-7
Liquid
imm
Acrylonitrile
107-13-1
Liquid
imm
Amido sulfonic acid (15%)
5329-14-6
Liquid
>480
Amino benzene
62-53-3
Liquid
imm
Ammonia (gaseous)
7664-41-7
Vapor
imm
Ammonium hydroxide (28% - 30%)
1336-21-6
Liquid
imm
Aniline
62-53-3
Liquid
imm
Benzenamine
62-53-3
Liquid
imm
Benzisothiazol 1,2- (20%)
2634-33-5
Liquid
>480
Black Liquor (mix)
mix
Liquid
>480
Bromine
7726-95-6
Liquid
imm
Butadiene, 1,3- (gaseous)
106-99-0
Vapor
imm
Butanal, n-
123-72-8
Liquid
imm
Butanol, 1-
71-36-3
Liquid
imm
Butanol, n-
71-36-3
Liquid
imm
Butyl alcohol, n-
71-36-3
Liquid
imm
Butyraldehyde, n-
123-72-8
Liquid
imm
Carbon disulfide
75-15-0
Liquid
imm
Carmustine (3.3 mg/ml, 10 % Ethanol)
154-93-8
Liquid
>240
Caustic ammonia (28% - 30%)
1336-21-6
Liquid
imm
Caustic soda (50%)
1310-73-2
Liquid
>480
Chemguard S-764P14A
mix
Liquid
>480
Chlorine (20 ppm)
7782-50-5
Vapor
>4808
Chlorine (gaseous)
7782-50-5
Vapor
imm
Chloro 2-nitrobenzene, 1-
88-73-3
Solid
15
Chloro acetic acid (80%)
79-11-8
Liquid
>480
Chloro ethanol, 2-
107-07-3
Liquid
imm
Chloroform
67-66-3
Liquid
imm
Cresol o-
95-48-7
Liquid
13
Cresols, mixed isomers
1319-77-3
Liquid
71
Cresylic acid
1319-77-3
Liquid
71
Cyanoethylene
107-13-1
Liquid
imm
Cyanomethane
75-05-8
Liquid
imm
Cyclo phosphamide (20 mg/ml)
50-18-0
Liquid
>240
Diaminoethane, 1,2-
107-15-3
Liquid
>480
Dichloro methane
75-09-2
Liquid
imm
Diesel automotive test fuel
mix
Liquid
imm
Diethyl amine
109-89-7
Liquid
imm
Dimethyl acetamide N,N- (30%)
127-19-5
Liquid
>480
Dimethyl acetamide, N,N- (8%)
127-19-5
Liquid
>480
Dimethyl formamide, N,N-
68-12-2
Liquid
imm
Dimethyl ketal
67-64-1
Liquid
imm
Dimethyl ketone
67-64-1
Liquid
imm
Diphenyl methane diisocyanate, 4,4'- (50 °C, molten)
101-68-8
Liquid
>480
Disodium sulfide (60% (slurry))
1313-82-2
Liquid
>480
Doxorubicin HCl (2 mg/ml)
25136-40-9
Liquid
>240
DuPont Activator 193S (mix)
mix
Liquid
>480
DuPont Activator 4505S (mix)
mix
Liquid
>480
DuPont Activator 4507S (mix)
mix
Liquid
>480
Epoxy ethane (gaseous)
75-21-8
Vapor
imm
Ethane 1,2-diol
107-21-1
Liquid
>480
Ethane nitrile
75-05-8
Liquid
imm
Ethyl acetate
141-78-6
Liquid
imm
Ethyl ethanamine, N-
109-89-7
Liquid
imm
Ethyl nitrile
75-05-8
Liquid
imm
Ethylene carboxylic acid
79-10-7
Liquid
imm
Ethylene chlorohydrin
107-07-3
Liquid
imm
Ethylene diamine
107-15-3
Liquid
>480
Ethylene glycol
107-21-1
Liquid
>480
Ethylene oxide (gaseous)
75-21-8
Vapor
imm
Ethylene tetrachloride
127-18-4
Liquid
imm
Etoposide (Toposar®, Teva) (20 mg/ml, 33.2 % (v/v) Ethanol)
33419-42-0
Liquid
>240
Fluorouracil, 5- (50 mg/ml)
51-21-8
Liquid
>240
Formalin (3.7%, 1-1.5% Methanol)
50-00-0
Liquid
>480
Formalin (37% (10-15% Methanol))
50-00-0
Liquid
imm
Fuel-oil no 2
68476-30-2
Liquid
imm
Glutaral (5%)
111-30-8
Liquid
>480
Glutaraldehyde (5%)
111-30-8
Liquid
>480
Glycol alcohol
107-21-1
Liquid
>480
Glycol chlorohydrin
107-07-3
Liquid
imm
Green Liquor (mix)
mix
Liquid
>480
Hexamethylene diisocyanate
822-06-0
Liquid
>480
Hexane, n-
110-54-3
Liquid
imm
Hydrochloric acid (37%)
7647-01-0
Liquid
140
Hydrofluoric acid (48-51%)
7664-39-3
Liquid
280
Hydrogen chloride (gaseous)
7647-01-0
Vapor
imm
Hydrogen fluoride (20-27 °C, gaseous)
7664-39-3
Vapor
imm
Hydrogen peroxide (30%)
7722-84-1
Liquid
>480
Hydrogen peroxide (50%)
7722-84-1
Liquid
>480
Hydrogen peroxide (70%)
7722-84-1
Liquid
>480
Hydroxy toluene, o-
95-48-7
Liquid
13
Isopropanol
67-63-0
Liquid
imm
Isopropanol (70%)
67-63-0
Liquid
imm
Isopropyl alcohol
67-63-0
Liquid
imm
Isopropyl alcohol (70%)
67-63-0
Liquid
imm
Ketone propane
67-64-1
Liquid
imm
Limonene d-
5989-27-5
Liquid
imm
Lithium chloride (20%)
7447-41-8
Liquid
>480
Lithium hydroxide (14.9%)
1310-65-2
Liquid
>480
Mercury
7439-97-6
Liquid
>480
Methanol
67-56-1
Liquid
imm
Methyl 2-pyrrolidone, N-
872-50-4
Liquid
imm.
Methyl 4-isopropenyl-1-cyclohexene, 1-
5989-27-5
Liquid
imm
Methyl acetyl
67-64-1
Liquid
imm
Methyl benzol
108-88-3
Liquid
imm
Methyl chloride (gaseous)
74-87-3
Vapor
imm
Methyl cyanide
75-05-8
Liquid
imm
Methyl ketone
67-64-1
Liquid
imm
Methyl phenols
1319-77-3
Liquid
71
Methyl salicylate
119-36-8
Liquid
<15
Methylene chloride
75-09-2
Liquid
imm
Methylene diphenyl diisocyanate, 4,4'- (50 °C, molten)
101-68-8
Liquid
>480
Mineral spirit
64475-85-0
Liquid
imm
Nitric acid (70%)
7697-37-2
Liquid
213
Nitro benzene
98-95-3
Liquid
imm
Nitro chlorobenzene, p-
100-00-5
Solid
imm
Nitro toluene, p-
99-99-0
Solid
imm
Oleum (103% (13% free SO3))
8014-95-7
Liquid
230
Oleum (20% free SO3)
8014-95-7
Liquid
60
Paclitaxel (Hospira) (6 mg/ml, 49.7 % (v/v) Ethanol)
33069-62-4
Liquid
>240
Pentanedial, 1,5- (5%)
111-30-8
Liquid
>480
Phenol (85%)
108-95-2
Liquid
11
Phenyl amine
62-53-3
Liquid
imm
Phosphoric acid (85%)
7664-38-2
Liquid
>480
Polymethylene polyphenyle isocyanate (p-MDI)
9016-87-9
Liquid
>480
Potassium cyanide (10%)
151-50-8
Liquid
>480
Potassium hydroxide (45%)
1310-58-3
Liquid
>480
Potassium permanganate (sat)
7722-64-7
Liquid
>480
Propan -2-ol
67-63-0
Liquid
imm
Propan -2-ol (70%)
67-63-0
Liquid
imm
Propan -2-one
67-64-1
Liquid
imm
Propene acid
79-10-7
Liquid
imm
Propenenitrile, 2-
107-13-1
Liquid
imm
Propenoic acid nitrile
107-13-1
Liquid
imm
Pyroacetic ether
67-64-1
Liquid
imm
Sodium cyanide (45%)
143-33-9
Liquid
>480
Sodium hydroxide (50%)
1310-73-2
Liquid
>480
Sodium hypochlorite (15%)
7681-52-9
Liquid
>480
Sodium hypochlorite (5.25-6%)
7681-52-9
Liquid
>480
Sodium metabisulphite (38%)
7681-57-4
Liquid
imm
Sodium silicate (40-42%)
6834-92-0
Liquid
>480
Spectracide® (50% Malathion, 44% Aromatic Solvent)
mix
Liquid
imm
Sulfamic acid (15%)
5329-14-6
Liquid
>480
Sulfamidic acid (15%)
5329-14-6
Liquid
>480
Sulfur dioxide
7446-09-5
Vapor
imm
Sulfuric acid (>95%)
7664-93-9
Liquid
>480
Sulfuric acid fuming (103% (13% free SO3))
8014-95-7
Liquid
230
Sulfuric acid fuming (20% free SO3)
8014-95-7
Liquid
60
Tetrachloro ethylene, 1,1,2,2-
127-18-4
Liquid
imm
Tetrahydrofuran
109-99-9
Liquid
imm
Tetramethyl ammonium hydroxide (25%)
75-59-2
Liquid
>480
Thiotepa (10 mg/ml)
52-24-4
Liquid
>240
Toluene
108-88-3
Liquid
imm
Toluene diisocyanate, 2,4-
584-84-9
Liquid
imm
Toluene diisocyanate, 2,4- (80%)
584-84-9
Liquid
60
Trichloro benzene, 1,2,4-
120-82-1
Liquid
imm
Trichloro methane
67-66-3
Liquid
imm
Trifluoro ethanol, 2,2,2-
75-89-8
Liquid
imm
Vinyl cyanide
107-13-1
Liquid
imm
Vinyl ethylene (gaseous)
106-99-0
Vapor
imm
White Liquor
mix
Liquid
>480

Important Notehelp

SPECIAL WARNINGS

View by: View all resources ✕ ✕ To access secured content from DuPont Please Sign In or Sign Up below Sign In New User ? Sign Up